8.

Cue Codes

Display
Meaning of Code
Code
no
1. The calibration weight
value is not loaded according
to the display when
calibrating.
2. The quantity of objects is
not loaded according to the
quantity of sampling.
dc.L
The batteries are brownout.
Err-0
The calibration data is lost
2. The load cell or main board
maybe damaged.
Err-1
1. The weight is over the max
capacity.
2. Lost the calibration data.
3. The load cell or main board
maybe damaged.
--L--
Lower limit alarm
--H--
Upper limit alarm
9.

Maintenance

In order to keep the scale's normal operating, the crust of indicator and the
platform of scale should be kept clean and prevented from corrosion by foreign
substance. If necessary, you should use a piece of cloth with mild washing agent
to clean them. When you don't use the scale, pull out the A/C plug. If not being
used in a long time, please take out the batteries
ANYLOAD ES310 Postal & Shipping Scale User's Manual (V1611)
10 |
Solution
1. Load the weight value
according to the show value.
2. Load the quantity according
to the show value.
1. Use new batteries.
2. Use power adapter.
Re-calibrate.
2. Change the Loadcell or main
board.
1. Remove the objects on the
platform.
2. Re-calibrate.
3. Change the loadcell or main
board.
1. cancel lower limit alarm
1. cancel upper limit alarm