Provide 4-bit DIP switch for function setting,
where "ON" is enable valid terminal. Please
power off and power on after changing the status
of DIP switch. DIP switch definition as follow:
DIP
Decscription
Operation
1
Reserved
—
2
Restore factory
Set the switch to ON, power on
setting
again, it restores to factory
defaults, set the switch back.
3
Reserved
—
4
Reserved
—
【Serial Port Connection】
RS232 and 3IN1 RJ45 interface
Model I, Model II, Model III, and Model IV
provide 3IN1 serial port that supports
1
8
RS-232/485/422. The interface is RJ45; Model
V, Model VI, Model VII, and Model VIII support
RS-232. The interface is RJ45.
The RJ45 PIN definitions are as follows.
PIN
1
2
3
4
RS-232
DSR RTS GND TXD RXD DCD CTS DTR
RS-485
—
—
GND —
RS-422
—
R-
GND R+
RS-485/422 Port
Model IX, Model X, Model XI, and Model
XII provide 5-pin 5.08mm pitch industrial
terminal block. The PIN definitions are as
follows.
PIN
1
2
3
RS-422
T+
T-
GND
RS-485
D+
D-
GND
【Checking LED Indicator】
The device provides LED indicators to monitor the device
working status with a comprehensive simplified
troubleshooting; the function of each LED is described in the
table as below:
LED
PWR
RUN
LINK (1-2)
TX
5
6
7
8
Port(1-4/8)
—
D-
—
D+
RX
—
T-
—
T+
Port(1-4/8)
【Logging in to WEB Interface】
This device supports WEB management and configuration.
Computer can access the device via Ethernet interface. The
way of logging in to device's configuration interface via IE
browser is shown as below:
4
5
R+
R-
—
—
Single-port
configuration. Please note the single and double port identifier in
front of the steps.
Indicate Description
The power connection is working
ON
normally.
The power is not connected or is
OFF
not working normally.
The system is not running
ON
normally.
Blinking
The system is running normally.
The system is not running or
OFF
running abnormally.
The LAN interface has established
ON
an active network connection.
The LAN interface is in an active
Blinking
network state.
The LAN interface has not
OFF
established an active network
connection.
No data or abnormal data is being
OFF
received through serial port.
Blinking
Serial port is receiving data.
No data or abnormal data is being
OFF
transmitted through serial port.
Blinking
Serial port is transmitting data.
Note
and
double-port
products
Single-port product: Model I, Model III, Model V,
Model VII, Model IⅩ and Model XI.
Double-port product:Model II, Model IV, Model VI,
Model VIII, Model Ⅹ and Model ⅩII.
Step 1
(Single port) Configure the IP addresses of
computer and the device to the same network
segment, and the network between them can be
mutually accessed.
Step 2
(Double port) Configure the IP addresses of
computer and the device to the same network
segment(The network segment of Network Port 1 is
1, and the network segment of network port 2 is 8),
and the network between them can be mutually
accessed.
Step 3
(Single port)Enter device's IP address in the
address bar of the computer browser.
Port1:
Step 4
(Double port)Enter device's IP address in the
address bar of the computer browser.
Port1:
Port 2:
Step 5
Enter device's username and password in the login
window as shown below.
have
different
Step 6
Click "OK" button to login to the WEB interface of
the device.