Duevi RX2 AP Інструкція з експлуатації - Сторінка 4
Переглянути онлайн або завантажити pdf Інструкція з експлуатації для Приймач Duevi RX2 AP. Duevi RX2 AP 4 сторінки. 2 channels wireless receiver
6. CONNECTING DIAGRAM
JP2 closed = programming
JP2 chiuso = apprendim.
JP2 open = working
JP2 aperto = normale
JP1
LEAVE ALWAYS OPEN
JP2
open
Working Mode
closed
Programming Mode
JP3
open
Impulsive Outputs
closed
Bistable Outputs
C13
open
Sensor and Remote Controls MODE
closed
ONLY Remote Controls MODE
7. TECHNICAL FEATURES
CHANNELS
OUTPUTS
BUZZER OUTPUTS
RANGE
FREQUENCY
POWER SUPPLY
DIMENSIONS
4
JP2
out RL1 out RL2
2 alarm channels, with selectable impulsive or bistable working mode
2 relays, one per channel.
for acoustic test of wireless range
100m in open field
>430 MHz
12 Vdc - 15 mA
150 x 100 x 45 mm
This manual can be modified without any advice
JP3 chiuso = canale1 bistabile
JP3 closed = bistable outputs
JP3 aperto = canale 1 monostabile
JP3 open = impulsive outputs
JP3
C13 open = sensors and remote controls
C13 closed = ONLY remote controls
C13
JP1 chiuso = 12 bit
JP1 ALWAYS OPEN
JP1 aperto = 48 bit
Reset
S1
JP1
Lighted on
LD1
Free Position
LD2
Occupied Position
LD3
Channel 1
LD4
Channel 2
RX2AP V2.4