3P Technik 1000650 Інструкція з експлуатації - Сторінка 4
Переглянути онлайн або завантажити pdf Інструкція з експлуатації для Системи фільтрації води 3P Technik 1000650. 3P Technik 1000650 4 сторінки. Rainwater filter for bigger roof areas
Cleaning and Maintenance:
Recommended Accessories:
Wall bracket for Twinfilter for installation on the wall
The wall mounting bracket for the Twin Filter* is required for wall installation.
The brackets are fastened to the wall at the desired height (heavy duty steels).
Push the filter rear side first into the recesses provided and fix using the
enclosed washers and nuts. Ensure filter sits horizontally for optimal
functioning. All UK filters come with a wall bracket. Item No. 1000655
*as accessorie available
Guarantee:
3P Technik Filtersysteme GmbH offers this product the guarantee required by law
(from date of purchase).
Öschstraße 14
73072 Donzdorf - Germany
T +49 (0) 71 62 - 94 60 7-0
F +49 (0) 71 62 - 94 60 7-99
www.3ptechnik.com
Cleaning: Spray the inside of the filter with water, clean the sump.
Remove the filter inserts and rinse with water. High-pressure
cleaners may also be used.
Afterwards loosen the filter mash with an Allen key. To degrease the
mesh fabric (pollen, heating oils, etc.) the mesh must be thoroughly-
cleaned using a detergent and a brush.
Rinse well, re-insert the mesh, place the cascade inserts back
into the filter.
Maintenance: In the first year, check the filter every three months,
to obtain an idea of the degree of contamination, then clean
as required, at least twice a year.