In condition of high water usage and/or high level of hydrogen sulfide, the unit
may need to regenerate more frequently than the standard three day cycle. The
unit can be set for every other day regeneration or daily regeneration, as
required. Do not set the regeneration frequency of longer than every three
days.
SETTING THE TIME OF DAY
Press and hold the Up or Down
buttons until the programming icon
replaces the service icon and the
parameter display reads TD.
Adjust the displayed time with
the Up and Down buttons.
When the desired time is set,
press the Extra Cycle button to resume
normal operation. The unit will also
return to normal operation after 5
seconds if no buttons are pressed.
INITIATING A REGENERATION
Press the Extra Cycle
button. The service icon
will flash to indicate that
regeneration is queued.
To cancel a queued
regeneration press
the Extra Cycle Button.
Regenerate Immediately
Press and hold the Extra
Cycle button for five
seconds.