Problem
No Display on PC Board
Circuit Board does not display
correct time of day
Control valve regenerates at
wrong time of day
Time of day flashes on and off
Unit does not regenerate
Unit does not draw air in "BD"
cycle
Water to drain continuously
Air in house line or at faucets
Control cycles continuously

Troubleshooting

Possible Cause
No power at electric outlet
Control valve Power Adapter not
plugged into outlet
Defective Power adapter
Defective Circuit Board
Power Outage
Power Adapter plugged into electric
outlet controlled by light switch
Tripped breaker switch and/or tripped
GFI
Power Outage
Time of day not set correctly
Time of regeneration set incorrectly
Power Outage
Electrical Service to unit is interrupted
Power failure
Not Programmed
Defective Timer
Injector is plugged
Injector screen is plugged
Line to drain is crimped or plugged
Drain line flow control is plugged
Line pressure is too low
Internal control leak
Main drive gear grooved
Motor stopped or jammed
Foreign material in control
Internal control leak
Main drive gear grooved
Iron Genie regenerating at same time
as other equipment is regenerating
Worn seals
Distributor O-ring damaged
Inadequate water supply to meet
backwash requirements
Misadjusted, broken, or shorted switch
Solution
Repair outlet or use working outlet
Plug Power Adapter into outlet
Replace Power Adapter
Replace Power Head Assembly
Reset time of day
Use uninterrupted outlet
Reset breaker switch and/ or GFI switch
Reset to correct time of day
Reset to correct time of day
Reset regeneration time
Press any button to stop the time of day
from flashing
Use uninterrupted outlet. Reset time of
day
Reset time of day
Enter Master Programming mode and
verify that the unit is configured properly
Verify that days advance on main display.
If not replace Power Head Assembly
Clean or replace injector throat and
nozzle
Clean or replace injector screen
Replace drain line
Clean drain line flow control
Increase line pressure to minimum of 20
psi
Replace seals and spacers
Replace main drive gear
Replace motor if necessary
Remove power head assembly and
inspect bore. Remove foreign material
and check control in various regeneration
positions
Replace seals and spacers
Replace main drive gear
Reset to correct time of day and verify
regeneration time of all equipment
Replace seals and spacers
Replace distributor O-ring
Verify water supply and proper flow rate
Determine if switch or timer is faulty and
replace it, or replace complete power
head assembly