Danfoss AK-CC55 Посібник з монтажу - Сторінка 11

Переглянути онлайн або завантажити pdf Посібник з монтажу для Контролер Danfoss AK-CC55. Danfoss AK-CC55 18 сторінок. Single coil
Також для Danfoss AK-CC55: Посібник з монтажу (16 сторінок)

Danfoss AK-CC55 Посібник з монтажу
Single Coil - continued
S6 alarm time delay
With setting = 240 the S6 alarm will be omitted
Alarm time delay or signal on the DI1 input
Alarm time delay or signal on the DI2 input
Signal for alarm thermostat. S4% (100%=S4, 0%=S3)
Delay for S6 (product sensor alarm) after defrost
Delay for temperature alarm, section B
Product sensor S6 function
Compressor
Min. ON-time
Min. OFF-time
Time delay for cutin of comp. 2
Switch mode for 2 compressor operation.
= 1 sequentially. = Cyclic 2
Defrost
Defrost method: 0=No, 1= EL, 2= gAs. 4=air
Defrost stop temperature
Interval between defrost starts
Max. defrost duration
Displacement of time on cut-in of defrost at start-up
Drip off time
Delay for fan start after defrost
Fan start temperature
Fan cut-in during defrost
0: Stopped
1: Running
2: Running during pump down and defrost
3: Running but stops at the temperature set in d41
Defrost sensor: 0 =Stop on time, 1=S5, 2=S4
Pump down delay
Drain delay (used at hot gas defrost only)
Max. aggregate refrigeration time between two
defrosts
Adaptive defrost:
0=not active, 1=monitoring only, 2=skip allowed day,
3=skip allowed both day and night, 4=own assessment
+ all schedules
Time delay before opening of hot gas valve
Rail heat during defrost
0=off. 1=on. 2=Pulsating
Max. duration of -d- in display
Temperature limit for fan stop during defrost when d09
is set to 3
Injection control function
Max. value of superheat reference
Min. value of superheat reference
MOP temperature. Off if MOP temp. = 15.0 °C
Cycle time of AKV pulsation
Only for trained personnel
Fan
Fan stop temperature (S5)
Pulse operation on fans: 0=No pulse operation, 1=At
thermostat cut-outs only, 2= Only at thermostat
cut-outs during night operation
Cycle time for fan pulsation (on-time + off-time)
On-time in % of cycle time
© Danfoss | DCS (vt) | 2019.07
R-W
Code
1
2 3
4
1-2
A26
1
1
1
1
1-2
A27
1
1
1
1
1-2
A28
1
1
1
1
1-2
A36
1
1
1
1
1-2
A52
1
1
1
1
1-2
A53
1-2* a01
1
1
1
1
1-2
c01
1
1
1
1-2
c02
1
1
1
1-2
c05
1-2
c08
1-3
d01
1
1
1
1
1-2
d02
1
1
1
1
1-2
d03
1
1
1
1
1-2
d04
1
1
1
1
1-2
d05
1
1
1
1
1-2
d06
1
1
1
1
1-2
d07
1
1
1
1
1-2
d08
1
1
1
1
1-2
d09
1
1
1
1
1-2
d10
1
1
1
1
1-2
d16
1
1
1
1
1-2
d17
1-2
d18
1
1
1
1
1-2* d21
1
1
1
1
1-2
d23
1-2
d27
1
1
1
1
1-2
d40
1
1
1
1
1-2
d41
1
1
1
1
1-2
n09
1
1
1
1
1-2
n10
1
1
1
1
1-2
n11
1
1
1
1
1-2* n13
1
1
1
1
1-2
F04
1
1
1
1
1-2
F05
1
1
1
1
1-2
F06
1
1
1
1
1-2
F07
1
1
1
1
5
6 7
8
9
Min.
1
1
1
0 min.
1
1
1
0 min.
1
1
1
1
1
0 min.
1
1
1
1
1
0 %
1
1
1
0 min.
1
1
0 min.
1
1
1
1
1
0/Off
1
0 min.
1
0 min.
1
0 sec
1
1
1
1
1
1
1
0/No
1
1
1
1
1
0°C
1
1
1
1
1
0 hrs/Off 240 hrs
1
1
1
1
1
0 min.
1
1
1
1
1
0 min.
1
1
1
1
1
0 min.
1
1
1
1
1
0 min.
1
1
1
1
1
-50 °C
1
1
1
1
1
0
1
1
1
1
1
0
1
1
1
1
1
0 min.
1
0 min.
1
1
1
1
1
0 hrs
1
1
1
1
1
0
1
0 min.
1
1
1
1
1
0
1
1
1
1
1
5 min.
1
1
1
1
1
-20 °C
1
1
1
1
1
"n10"
1
1
1
1
1
2 °C
1
1
1
1
1
-50 °C
1
1
1
1
1
3 sec
1
1
1
1
1
-50 °C
1
1
1
1
1
0
1
1
1
1
1
1 min.
1
1
1
1
1
0 %
AN294432763974en-000201 | 11
Max.
Fac.
Actual
240 min.
60
240 min.
30
240 min.
30
100 %
100
240 min.
90
240 min.
30
1/On
0/Off
30 min.
0
30 min.
0
999 sec
5
2
2
4/Air
1/EL
50 °C
6
8
360 min.
45
240 min.
0
60 min.
0
60 min.
0
10 °C
-5
3
1
2
0
60 min.
0
60 min.
0
240 hrs
0/OFF
4
0
60 min.
0
2
1
240 min.
30 min.
20 °C
0
20 °C
12
"n09"
3
15 °C
15
6 sec
6
50 °C
50
2
0
30 min.
5
100 %
100