Duke Energy EnergyWise Business Посібник користувача - Сторінка 3
Переглянути онлайн або завантажити pdf Посібник користувача для Перемикач Duke Energy EnergyWise Business. Duke Energy EnergyWise Business 7 сторінок.
Link LED
The Link LED is used to indicate the status of the communication link. When it stays on solid, it indicates good end-to-end
communication with the controlling software system. If any link along the communication chain is lost, the LED will blink in
different patterns as shown below.
Link LED Operation Table
Link LED
Off
0.5 second blink
1 second on, 3 seconds off blink
3 seconds on, 1 second off blink
Solid On
Test LED
The Test LED is used by the installer during installation. When the device is first powered up, the Test LED will flash either
once or twice to indicate cold or warm starts, respectively. The Test LED can also be manually toggled by the installer to test
end-to-end communication with the software using the installer's test tool. In normal operation, this LED should be off.
Relay LED
The relay LED(s) is used to indicate whether the appliance is prevented from running during a conservation period. It is turned
on whenever the appliance (HVAC) is being controlled and is prevented from running. When used with HVAC,
is cycled on and off periodically. This allows some amount of cooling/dehumidification as well as air circulation during the
control period to minimize customer discomfort. This LED will turn on during the times when the HVAC is turned off.
HVACs may have multiple compressor stages. In these installations, each relay is used to control each stage of the compressor and both relays will open at
*
the same time to prevent both stages of the compressor from running during a conservation period.
EnergyWise
Business Wi-Fi Switch User Manual
®
Status
Client mode - no network connection
Ad-hoc mode – IntelliPEAK is creating its own
Wi-Fi network to allow entry of credentials
Client mode - Wi-Fi network connected, waiting
for Internet connection
Client mode – Wi-Fi/Internet network connected,
but not connected to controlling software
Client mode - Cellular/Internet/software
connection OK
the compressor
*