Dunavox DAB-89.215DB Інструкція з експлуатації - Сторінка 7

Переглянути онлайн або завантажити pdf Інструкція з експлуатації для Охолоджувач для вина Dunavox DAB-89.215DB. Dunavox DAB-89.215DB 20 сторінок.
Також для Dunavox DAB-89.215DB: Інструкція з експлуатації (16 сторінок)

Dunavox DAB-89.215DB Інструкція з експлуатації
FULLY INTERGRATED BUILT-IN-COLUMN
INSTRUCTIONS
The unit door seals the installed unit almost
completely, so an air vent must be provided in the
base of the housing. Warmed air must be conducted
via the ventilation shaft to the rear wall of the
housing and then expelled upwards. The ventilation
channels should measure at least 200 square
centimeters in cross-section.
A (mm)
45cm H
444
60cm H
584
88cm H
874
122cm H
1223
177cm H
1773
Remark: The dimension A does not include the
adjustable legs and the units are permitted to be
installed without the adjustable legs.
WARNING: To ensure the proper functioning of the
appliance, air vents should never be blocked or
covered.
Code Rev. D 20140818 (IEC)
B (mm)
C (mm)
455
450
595
590
885
874-880
1234
1223-1230
1784
1773-1780
BUILT-IN CABINETRY INSTRUCTIONS
Make sure your installation does not block the front
ventilation grille. And be sure the door will open and
close properly in the chosen location.
A (mm)
100
1480
125
1772
170
1772

ELECTRICAL CONNECTION

WARNING:
Improper use of the grounded plug
can result in the risk of electrical shock. If the power
cord is damaged, have it replaced by a qualified
electrician or an authorized service center.
All electrical work should be carried out by a suitably
qualified and competent person in accordance with
local and national safety regulations.
Check that the voltage marked on the product
corresponds with your supply voltage.
Connect this appliance to a separate at least 13A
circuit.
Connection should be made via a suitable switched
socket which is easily accessible. For extra safety it
is advisable to install a residual current device (RCD)
with a trip current of 30mA.
Have the receptacle and the circuit checked by a
qualified electrician to ensure that the socket is
grounded correctly.
Note: In locations where there is frequent lightning,
it is advisable to use surge protectors.
Do not connect the appliance to the mains electricity
supply by an extension lead. Extension leads do not
7
B (mm)
C (mm)
D (mm)
550
1476
550
1768
660
1768
570
570
680