CashCode BNL-3008 Посібник користувача - Сторінка 2
Переглянути онлайн або завантажити pdf Посібник користувача для Лічильник банкнот CashCode BNL-3008. CashCode BNL-3008 2 сторінки. Bnl bill validator
1. Typical DIP Switches Setting
To access switches open the back lid. Switches are located on the right side of
the lid, as observed from the bezel. The "up" state is defined as the switch
position closer to the top cover of the lid.
"Down" State
SW. #1
SW 1.1
1-st Bill Enable controlled by host
SW 1.2
2-nd Bill Enable controlled by host
SW 1.3
3-rd Bill Enable controlled by host
SW 1.4
4-th Bill Enable controlled by host
SW 1.5
5-th Bill Enable controlled by host
SW 1.6
6-th Bill Enable controlled by host
SW 1.7
7-th Bill Enable controlled by host
SW 1.8
8-th Bill Enable controlled by host
"Down" State
SW#2
SW 2.1
Four Way
SW 2.2
High security disabled
SW 2.3
19200 bps data rate
SW 2.4
Not used
2. Interface Connector Pinout
Mating Connector:
Socket 43025-1200 (Molex);
Contact 43030-0002 (Molex).
Terminal
1
2
3
4
5
6
7
8
9
10
11
12
"Up" State
1-st bill Disable
2-nd Bill Disable
3-rd Bill Disable
4-th Bill Disable
5-th Bill Disable
6-th Bill Disable
7-th Bill Disable
8-th Bill Disable
"Up" State
One Way
High security enabled
9600 bps data rate
Not used
7
8
9 10 11 12
1
2
3
4
5
6
Circuit
Signal Ground
RS232_DATA_TO_PC
GND
GND
+12V
+12V
RS232_DATA_FROM_PC
BUS RESET
GND
GND
+12V
+12V
3. Power connections
+12 V lines must be connected together directly at the connector.
Power ground lines must be connected together directly at the connector,
thus forming a power ground star point; 12V power source must use this star
Default
point.
down
down
down
Signal ground may not be connected to power ground star point; it should be
down
connected to the host signal ground instead.
down
down
Bus reset line, host Rx and Tx lines are all RS232 signal level lines.
down
down
4. Diagnostics
Default
down
Count the number of flashes and compare with the diagnostic chart below:
down
down
## of
Malfunction
down
flashes
Boot-related flashes (green flashes on red background)
Memory write error – check memory stick for proper contact
1
Firmware set incomplete – please obtain the missing part and
2
install
A required card is missing – please install the card required;
3
normally reported when the main firmware component is
missing/corrupt
Update policy violation – please install the card required to
regain policy rights; most common reason – a ONE UPDATE
4
or NDEG card is missing
Generic error – a fatal boot error, please contact technical
5
support
Box removed – please verify the drop box is secured in place
1
Boot invocation error – please verify that a required card is in
2
place
Box full – check the drop box and make sure it's not full
3
Stacker plate stuck – verify that drop box is fully inserted and
4
stacker plate has room to move inside the drop box
Optical sensor failure – contact technical support
6
Magnetic sensor failure – contact technical support
7
Bill jam – please verify the bill pathway is clear
11
Firmware integrity problem – please verify that all firmware
14
components are installed
Operation flashes (red flashes on dark background)