4.3 X2.1-X2.4 Motor Connectors M23 (in M25)
Female
General ratings
•
Pins 1, 2, 3 and 4: 480 V AC, maximum 15 A
•
Pins C and D: 30 V DC, maximum 3 A
•
Tightening torque: 1.5–2.0 Nm
Pin
Label
Connected to frequency
converter wiring schematic
1
U
3
V
4
W
2
PE
Table 4.3 Wire/Connector Assignment for Plug X2
Mating part: Motor X2 (male)
Phoenix order number.: KCX-K0341/XX,XX
Max. cable length 7.0 m
4.4 2 Motor Connection Variant (134N3195)
Keep blind plugs installed at all times to keep the enclosure
tight.
Label
Connected to frequency converter wiring schematic
X2.1-B
53
X2.2-A
50
X2.1-A and
Connected to a common terminal
X2.2-B
X2.1-C and
Connected to an open terminal available in the
X2.2-C
frequency converter
X2.1-D and
Connected to an open terminal available in the
X2.2-D
frequency converter
Table 4.4 2 Motor Connection
4.5 4 Motor Connection Variant (134N3196)
Label
Connected to frequency converter wiring schematic
X2.1-B
53
X2.4-A
50
X2.1-A and
Connected via an internal terminal
X2.2-B
X2.2-A and
Connected via an internal terminal
X2.3-B
X2.3-A and
Connected via an internal terminal
X2.4-B
Table 4.5 4 Motor Connection
MI04G102
VLT® AutomationDrive FC 302 with Connectors
Min. wire
2
[mm
]
96 (U)
2.5
97 (V)
2.5
98 (W)
2.5
95
2.5
Danfoss A/S © Rev. 06/2014 All rights reserved.
4.6 X51 PROFIBUS M12 Male, X52 PROFIBUS
M12 Female
General ratings
•
30 V DC, maximum 1 A
•
Tightening torque: 0.2–0.3 Nm
Label
Connected to frequency converter PROFIBUS
connector
1
5 V DC
2
3
0 V DC
4
Table 4.6 PROFIBUS Connection
Mating part: PROFIBUS X52 and X51 (female/male)
Phoenix order number.: SAC-2P-MSB/ XX,XX-910/FSB SCO CT
4.7 X11-X14 I/O Connector Box
Phoenix sensor/actuator box - SACB-4/4-L-0,57HPUR CDA -
1531426
Tightening torque slot sensor/actuator cable 0.4 Nm
Label
Wire
Connected to frequency
converter wiring schematic
X11-X14 1
Brown
X11-X14 2
X11-X14 3
Blue
X14-4
Grey
X13-4
Yellow
X12-4
Green
X11-4
White
Table 4.7 Connector Box