Danfoss TP75B Посібник з монтажу та введення в експлуатацію - Сторінка 2

Переглянути онлайн або завантажити pdf Посібник з монтажу та введення в експлуатацію для Терморегулятор Danfoss TP75B. Danfoss TP75B 4 сторінки. Electronic programmable room thermostats with integral sensor, with remote sensor, with remote teleswitch, with remote sensor & teleswitch
Також для Danfoss TP75B: Інструкція з налаштування (4 сторінок)

Danfoss TP75B Посібник з монтажу та введення в експлуатацію
Fig. 2 TP75 or TS2 location
1a.
TP75
Select the desired fixing position. (This should
adhere to normal room thermostat practice, see Fig. 2).
1b.
TP75A
Select the desired fixing position for the TS2
remote sensor. (This should adhere to normal room thermostat
practice, see Fig. 2). Select the desired fixing position for the
TP75A. 1·0mm² solid copper cable should be used to connect
the TP2 to the TP75A. Note that
a)
the cable length should not exceed 50 metres,
b)
to avoid electrical interference the cable should not be run
parallel in close proximity to other cables carrying mains
electricity, and where necessary the cable should cross
over mains cabling at right angles.
2.
When fixing the heating controller wallplate note that the terminals
are at the top and the vertical centre line of the heating controller
is at the right hand edge of the terminal 4 recess. Observe the
clearance required for fitting and removal, Fig. 3.
3.
Fix the wallplate to the wall or plaster box as required.
4.
Make the wiring connections for the system control circuits, (and
remote sensor when used).
5.
Surface cables can only enter from below the unit. If mounted on
a plaster box cables can enter from the rear through the aperture
in the wallplate.
6.
These models do not require an earth connection. However, an
earth terminal is provided on the wallplate to ensure earth
continuity for the connections to the heating plant. (A neutral
looping terminal is also provided.)
7.
The diagrams on the next page show typical wiring circuit's with
which the units may be used, together with terminal to terminal
wiring information for use with the WB12 Wiring Box included
with Heatshare and Heatplan Control Packs.
8.
Clear all dust and debris from the area.
9.
Before fixing the unit on to its wallplate, ensure that the four DIL
switches on the rear of the unit (see Fig. 4) have been moved to
the required settings; the choices are:-
5/2 day
OSC ON
Chrono 6
10.
Position the slots in the top surface of the module over the lugs
at the top of the wallplate, and hinge downwards until the module
is pressed fully against the wallplate. Tighten the two screws
from below to fix the module to the wallplate.
11.
Before setting the programmes the unit and circuits should be
checked. Refer to the following Commissioning Instructions.
7 day
OSC OFF
ON/OFF
Chrono 3