Save the controllers present settings to the programming key. Select your own number.
Load a set of settings from the programming key (previously saved via o65 function)
Replace the controllers factory settings with the present settings
Select application for S5 sensor (0=defrost sensor, 1= product sensor, 2=condenser sensor with alarm)
Service
Temperature measured with S5 sensor
Status on DI1 input. on/1=closed
Status on night operation (on or off ) 1=closed
Read the present regulation reference
Status on relay for cooling (Can be controlled manually, but only when r12=-1)
Status on relay for fans (Can be controlled manually, but only when r12=-1)
Status on relay for defrost. (Can be controlled manually, but only when r12=-1)
Temperature measured with Sair sensor
Factory setting
If you need to return to the factory-set values, it can be done in this way:
- Cut out the supply voltage to the controller
- Keep upper and lower button depressed at the same time as you recon nect the supply voltage
Fault code display
E1
Fault in controller
E 27
S5 sensor error
E 29
Sair sensor error
EKC 102D
Alarm code display
A 1
High temperature alarm
A 2
Low temperature alarm
A 4
Door alarm
A 15
DI 1 alarm
A 45
Standby mode
A 59
Case cleaning
A 61
Condenser alarm
Instructions RI8KU567 © Danfoss 08/2010
o65
0
25
o66
0
25
o67
OFF
On
o70
0
2
u09
u10
u13
u28
u58
u59
u60
u69
Status code display
S0
Regulating
S2
ON-time Compressor
S3
OFF-time Compressor
S4
Drip-off time
S10
Refrigeration stopped by main switch
S11
Refrigeration stopped by thermostat
S14
Defrost sequence. Defrosting
S15
Defrost sequence. Fan delay
S16
Refrigeration stopped because of open DI
input
S17
Door open (open DI input)
S20
Emergency cooling
S25
Manual control of outputs
S29
Case cleaning
S32
Delay of output at start-up
non
The defrost temperature cannot be dis-
played. There is stop based on time
-d-
Defrost in progress / First cooling after
defrost
PS
Password required. Set password
0
0
OFF
0
5