Danfoss EKE 1P Посібник користувача - Сторінка 14
Переглянути онлайн або завантажити pdf Посібник користувача для Блок управління Danfoss EKE 1P. Danfoss EKE 1P 16 сторінок. Stepper valve extension module, adap-kool refrigeration control system
User Guide | Stepper Valve Extension Module, Type EKE 1P
Technical Data
General specification
Feature
Power supply
Power Consumption
Plastic Housing
Connectors
Operating conditions
Storage / Transport conditions
Vibration and shock
Integration
Index of protection
PCB protection
Period of electric stress across
insulating parts
Resistance to heat and fire
Immunity against voltage surges
Software class and structure
Approvals
Electrical specification
Feature
Type
Protection Short circuit
Over voltage
Over temperature
Unstable Digital input
Installation considerations
Accidental damage, poor installation, or site conditions, can give
rise to malfunctions of the control system, and ultimately lead to a
plant breakdown.
Every possible safeguard is incorporated into our products to
prevent this. However, a wrong installation, for example, could still
present problems.
Electronic controls are no substitute for normal, good engineering
practice.
14 | BC320219567793en-000201
Description
Galvanic isolation by switch mode power supply
Input voltage rating (AC): 24 V AC ± 20 % (19.2 – 28.8 V AC)
Input frequency (AC): 50 / 60 Hz
Input voltage rating (DC): 24 V DC (20 – 40 V DC)
Provides 5 W at 5 V and 15 V outputs isolated from the 24 V input
Insulation between power supply and the extra-low voltage
Total Power consumption with following valve in operation and MMIGRS2 connected to the controller:
CCMT 16 - CCMT 42 : 15 V A /10 W
ETS 6
: 11 V A / 7.5 W
ETS 12C - ETS 100C : 20 V A / 14 W
KVS C
: 20 V A / 14 W
ETS 12.5 - ETS 400
: 7 V A / 5 W
CCMT 2 - CCMT 8
: 7 V A / 5 W
CCMT 3L - CCMT 8L : 9 V A/ 6 W
CTR 20
: 7 V A / 5 W
DIN rail mounting complying with EN 50022
Self-extinguishing V0 according to IEC 60695-11-10 and glowing / hot wire test at 960 °C according to IEC 60695-2-12
Material used for Enclosure are UL94-V0 and RoHS compliant
Ball test: 125 °C according to IEC 60730-1
Leakage current: ≥ 250 V according to IEC 60112
Plug able Screw connector Pitch 3.5 mm, relay and power connector Pitch 5 mm, CAN MMI: Modular Jack 6P4C
Material used for connectors are RoHS and UL approved
-20 – 60 °C, 90% RH non-condensing
-30 – 80 °C, 90% RH non-condensing
According to IEC 60068-2-27 Ea
In Class I and / or II appliances
IP40 only on the front cover
None (no conformal coating)
Long
Category D
Category II
Class A
CE compliance:
This product is designed to comply with the following EU standards:
• Low voltage guideline: 2014/35/EU
• Electromagnetic compatibility EMC: 2014/30/EU and with the following norms:
– EN61000-6-1. EN61000-6-3
(immunity and emission standard for residential. commercial and light-industrial environments)
– EN61000-6-2. EN61000-6-4
(immunity and emission standard for industrial environments)
– EN60730-1 and EN60730-2-9
(Automatic electrical controls for household and similar use)
RoHS compliance to 2011/65/EU and no components from negative list acc. to 500B0751
UL approval
Description
Motor driver: dissipative over current protection
Analogue input: current limit and internal clamp diode
Digital input: current limit and internal clamp diode
Communication: transreceiver IC
Motor driver: thermal shutdown at 150 °C
Continuous variation of the digital input state
Danfoss will not be responsible for any goods, or plant
components, damaged as a result of the above defects. It is the
installer's responsibility to check the installation thoroughly, and
to fit the necessary safety devices.
Special reference is made to the necessity of signals to the
controller when the compressor is stopped and to the need of
liquid receivers before the compressors. Your local Danfoss agent
will be pleased to assist with further advice, etc.
© Danfoss | DCS (vt) | 2020.03