Danfoss APP W HC 15 Посібник з експлуатації - Сторінка 2

Переглянути онлайн або завантажити pdf Посібник з експлуатації для Водяний насос Danfoss APP W HC 15. Danfoss APP W HC 15 20 сторінок. Disassembling and assembling

Service guide | Disassembling and Assembling, APP 21 - 46 and APP W HC 15 -30

Table of Contents

1.

Introduction

2 | 180R9406 | AX274339308034en-000302
Contents
1.
Introduction .............................................................................................................................................................. 2
2.
Disassembling the pump ..................................................................................................................................... 3
3.
Assembling the pump .......................................................................................................................................... 6
4.
Disassembling and assembling of the swash plate ..................................................................................10
5.
Disassembling andassembling of cylinder barrel and valve plate ......................................................11
6.
Disassembling and assembling of the flush valve ....................................................................................11
7.
Changing pistons ..................................................................................................................................................12
8.
When should the pistons be replaced ...........................................................................................................17
9.
Exploded view APP 21-26 , APP 30/1500 and APP W HC 15-24 ..........................................................18
10.
This document covers the instructions for disassembling and assembling the axial piston pumps
APP 21-46 and APP W HC 15-30
Tools provided with toolset 180B4172:
10 mm combination wrench
13 mm combination wrench
6 mm allen key
Adjustable pin wrench
Stop for retainer plate
Press bush for valve plate
Shaft seal extractor ø45
M8 allen screw (20 mm and 140 mm)
Press bush ø45 (Plastic)
M8 mm eye bolt
M8 mm nut
M8 x 70 mm screw
Important: It is essential that the pump is
serviced in conditions of absolute cleanliness.
Place the pump on a pallet or other stable
surface above the ground. Ensure that the pump
cannot roll. It must be possible to place the pump
vertically with the shaft pointing downwards.
This can be done between two pallets or
between two boards on a pallet provided that
the distance is minimum 50 mm.
For a better understanding of the pump, please
see the exploded view on page 18 and 19.
WARNING:
Do not reuse disassembled O-rings or shaft
seal as they might be damaged. Always use
new O-rings.
© Danfoss | 2023.03