On the top-right of the Digital screen, the user can press the ON/OFF button
to enable/disable the supercapacitor-based 5V supply output and to control
supercapacitor charge/discharge state.
Depending on the charge state, pressing this button will behave as follows:
•
Capacitors Charging (output supply is disabled):
o
Short-press on Digital ON/OFF – determines the state of the output
supply when the charging is complete (state changes to Capacitors
Charged);
o
Long-press(5s) on Digital ON – enables the capacitor discharging
mode;
•
Capacitors Charged:
o
Short-press on Digital ON/OFF – enables or disables the output
supply;
o
Long-press(5s) on Digital ON – disables the output supply and
enables the capacitor discharging mode;
•
Capacitors Discharging or Capacitors Discharged (output supply is
disabled):
o
Short-press on Digital OFF – enables the capacitors charging mode.
The Reference ON/OFF button is used to enable/disable the supply used
for clocks.
Note: When the 5V supply is in Capacitors Charged mode and the Digital
button is set to ON, if an Audiobyte device (Hydra VOX/HUB) is connected
to the Hydra ZAP, the supply control is taken over by the ZAP and the user
cannot turn ON or OFF any of the supplies, individually. In this case, the
supplies can only be turned off by putting the Hydra ZAP in stand-by mode
from the home screen.