Daniamant L163 Інструкція з монтажу та обслуговування - Сторінка 4
Переглянути онлайн або завантажити pdf Інструкція з монтажу та обслуговування для Морський запобіжний пристрій Daniamant L163. Daniamant L163 6 сторінок. Mounting adapter plate
Також для Daniamant L163: Інструкція з монтажу та обслуговування (9 сторінок)
Installation
The L161 and L163 lights should be mounted so that when the lifebuoy is removed a direct pull is exerted
on the lanyard thus ensuring that the light is withdrawn from the container and switched on.
Screw the container to a secure location using all four fixing holes provided, making sure that when
deployed the drop to the water is not greater than 76 metres. The L161 and L163 Lifebuoy lights have
been constructed to withstand a drop into the water from up to 76M, in excess of what is required by LSA
Code (Chapter II Section 2.1.1.6).
Secure the lanyard to the lifebuoy. Ensure that the release toggle is fitted to the switch and that the
switch is in the off position as shown on page 3. Finally fit the light to the bracket with the lanyard fed
over the lip on the front. IMPORTANT: The lanyard must feed over the top edge of the bracket as shown
to ensure correct release.
Operation
The light is automatically switched on when the lifebuoy is deployed. As the lifebuoy is deployed, the
lanyard will lift the light from its mounting bracket. Upon leaving the bracket, the rip cord attached to the
switch will switch the light on. When switched on, the light will provide a flashing light of at least 2 Cd.
Once the light has been deployed, it must be considered expended and replaced with a new light.
Replacement
The L161 and L163 lights have a storage life of 5 years and must be replaced by the date shown on the
label.
Characteristics
Light output
Dimensions
Weight
Approvals
Safety
This light uses Lithium cells. These must be handled correctly:
— Do not dismantle battery pack
— Do not make any external electrical connection
— Do not recharge
— Do not incinerate
— Store between –30°C and +65°C
The lifebuoy lights are housed within plastic enclosures and may be susceptible to electrostatic charging.
When mounted in Zone 0, precautions shall be taken to ensure that electrostatic charging cannot occur.
L161
2 Cd minimum for 2 hours
174mm high x 101mmØ
Light 226g, Bracket 73g
SOLAS, ATEX
L163
2 Cd minimum for 15 hours
174mm high x 101mmØ
Light 245g, Bracket 73g
SOLAS, USCG, ATEX