Danish Interpretation Systems AO 6008 Посібник користувача - Сторінка 17

Переглянути онлайн або завантажити pdf Посібник користувача для Конференц-система Danish Interpretation Systems AO 6008. Danish Interpretation Systems AO 6008 18 сторінок. Digital conference system audio output unit with firmware 5.3.5 or later

Danish Interpretation Systems

Technical specifications

Digital Section
Sound quality ......... 20 bit audio @ 32 kHz sampling frequency
Analogue Section
Output signal type...............ground lifting transformer balanced
Nominal output level: ...........................0 dBm at nominal input
Max. Output level:..........................................................15 dBm
Frequency response .................................................... 50-15kHz
Signal to noise ratio: .................................................. >85 dBA
Total harmonic distortion: .............................................< 0.1%
General
Power requirement...................................................24-48 V DC
Power consumption ............................................. 5W maximum
Power supplied from
...................................CU 6005 / CU 6010 / EX 6010 / PS 6000
Temperature to guarantee specified performance
..............................5 Deg C. to 40 Deg C. (35 to 80% humidity)
Storage temperature
.......................... -20 Deg C. to 60 Deg C. (10 to 80% humidity)
Weight .............................................................................. 4,5 kg
Dimensions (W x H x D).......... 425 (483) x 87 x 317 (357) mm
dimensions in bracket are including 19" brackets
Accessories supplied .............................................. User manual
Connectors
DCS-LAN network............................................... 2 pieces RJ45
Analogue outputs connectors ........... 8 - XLR3 male connectors
Remote Control commands in/out
By using SW 6000 the user can control the AO 6008 through
the CU 6005/6010. A number of control messages are used for
this communication.
The CU 6005/6010 can read the following info from the AO
6008:
* ............................................................................... Error status
* ............................................ Channel number for each channel
* .............................................. Volume setting for each channel
* ........................................................................... Serial number
* .......................................................................Software version
* ......................................................................Hardware version
The CU 6005/6010 can control the following settings:
* .................................................... Volume steps for all channel
* .........Channel number for each output channel and headphone
* ......................Volume setting for each channel and headphone
* ................................................................. Error counter (reset)
The settings can be controlled from the SW 6000 or using the
AO 6008 User Interface (with exception of setting of volume
steps.
The CU 6005/6010 continuously monitors the status of the AO
6008 to ensure that updated status of the unit is always present
on the CU 6005/6010.
Specifications are subject to change without notice.
Manual 01 18 04440
User Manual
17