Danish Interpretation Systems EX 6010 Посібник користувача - Сторінка 10

Переглянути онлайн або завантажити pdf Посібник користувача для Джерело живлення Danish Interpretation Systems EX 6010. Danish Interpretation Systems EX 6010 19 сторінок. Digital conference system; extension power supply with repeater for increasing the system capacity in dds 5900 and dcs 6000 systems

DIS

Operating instructions

General description

The EX 6010 Extension Unit provides additional
Power Supplies, Repeater and Splitter functionality
for the DCS 6000 system. One CU 6105 or CU 6110
Central Unit is needed in each DCS 6000 system,
however for expansion of the system the EX 6010
Extension Unit is suitable. The EX 6010 consist of two
main parts:
Repeater/splitter board with 4 individual outputs
4 individual power supplies
User Controls, indications & connectors

Front plate layout

The EX 6010 Extension Unit features the following
Front plate controls
controls and display:
When power is switched ON at the CU 6105 or CU
Power Led
6110 Central Unit any connected EX 6010 Extension
Units will automatically be powered up. An LED
indicates when power is switched ON.
Fault LED
10

Features

The main features of the EX 6010 Extension Unit are:
This indication lights up, if the internal power supply
is malfunctioning i.e. because of overheating or
overload of a chain.
The Fault LED will always light up some seconds after
the unit is switched on caused by the delayed
switching on of the four supplies.
As a warning the light is flashing at an internal
temperature above 45°C. At a temperature above
55°C or if one of the DCS-LAN outputs is supplying no
voltage, the LED is lighting constantly.
Please note that the maximum ambient temperature
for the CU 6105 or CU 6110 is 40 deg. Celsius.
User Manual EX 6010 rev F.doc
Built in Power Supplies for app 200 units
(Delegate) or app. 600 Channel Selectors
4 outputs for connection to Delegate Units,
Interpreter Units etc.
Loop
through
connectors
additional EX 6010 or other units, which are part
of the DCS 6000 system
Delayed switching on of power to the four chains,
to minimise the total 'in rush' current on the
Mains supply.
Designed in a standard 2HE 19" cabinet.
User Manual CU 6105
for
connection