Belden HIRSCHMANN RS2-3TX/2FX EEC Опис та інструкція з експлуатації - Сторінка 4
Переглянути онлайн або завантажити pdf Опис та інструкція з експлуатації для Мережевий маршрутизатор Belden HIRSCHMANN RS2-3TX/2FX EEC. Belden HIRSCHMANN RS2-3TX/2FX EEC 10 сторінок. Industrial ethernet rail switch 2
ATEX Directive 94/9/EC –
Special conditions for safe use
Relevant for RS2-xTX/xFX EEC devices
when operating in explosive gas atmosphe-
res according to ATEX Directive 94/9/EC, the
following applies:
List of Standards:
- EN 60079-0:2009
- EN60079-15:2010
Certificate No.: DEKRA 13ATEX0013 X
Make sure that the device has the follo-
wing label:
II 3G Ex nA IIC T4 Gc DEKRA
13ATEX0013 X
Ambient rating and temperature code:
Ta: -40 °C ... +60 °C
The modules shall be installed in a sui-
table enclosure in accordance with EN
60079-15 providing a degree of protection
of at least IP54 according to EN 60529,
taking into account the environmental con-
ditions under which the equipment will be
used.
When the temperature under rated con-
ditions exceeds 70 °C at the cable or conduit
entry point, or 80 °C at the branching point
of the conductors, the temperature specifi-
cation of the selected cable and cable
entries shall be in compliance with the
actual measured temperature values.
Provisions shall be made to prevent the
rated voltage from being exceeded by tran-
sient disturbances of more than 119 V.
Connectors shall be connected or dis-
connected exclusively in dead-voltage state.
DIP switches shall be switched exclusi-
vely in dead-voltage state.
Safety Guidelines Environment
Warning!
z
The device may only be operated in
the listed surrounding air tempera-
ture and at the listed relative air
humidity (non condensing).
The installation location is to be selec-
ted so as to ensure compliance with the cli-
matic limits listed in the Technical Data.
To be used in an up to Pollution Degree
2 environment only (IEC 60664-1).
Staff qualification
requirements
Note: Qualified personnel, as understood
in this manual and in the warning signs, are
persons who are familiar with the setup,
assembly, startup, and operation of this
product and are appropriately qualified for
their job. This includes, for example, those
persons who have been:
– trained or directed or authorized to
switch on and off, to ground and to label
power circuits and devices or systems in
accordance with current safety enginee-
ring standards
– trained or directed in the care and use of
appropriate safety equipment in accor-
dance with the current standards of safety
engineering
– trained in providing first aid.
4
General Safety Instructions
This device is electrically operated.
Adhere strictly to the safety requirements
relating to voltages applied to the device as
described in the operating instructions!
Warning!
z
Failure to observe the information
given in the warnings could result in
serious injury and/or major damage.
Only personnel that have received
appropriate training should operate
this device or work in its immediate
vicinity. The personnel must be fully
familiar with all of the warnings and
maintenance measures in these
operating instructions.
Correct transport, storage, and
assembly as well as careful operati-
on and maintenance are essential in
ensuring safe and reliable operation
of this device.
Use only undamaged parts!
These products are only to be used in
the manner indicated in this version of the
"Description and Operating Instructions".
Particular attention is to be paid to all
warnings and items of information relating
to safety.
Warning!
z
Any work that may have to be per-
formed on the electrical installation
should be performed by fully quali-
fied technicians only.
Warning!
z
LED- or LASER components accor-
ding to IEC 60825-1:
CLASS 1 LASER PRODUCT.
LIGHT EMITTING DIODE - CLASS 1
LED PRODUCT.
Based specifications and
standards:
The devices fulfil the following specificati-
ons and standards:
– EN 61000-6-2 Basic standard –
interference resistance in industry.
– EN 55022 – Interference characteristics for
IT systems.
– EN 60950 – Security in IT systems.
– EN 61131 – Programmable Logic Control-
lers.
– CFR-47 Part 15 – Code of Federal Regulati-
ons.
– UL 508 – Underwriters Laboratories Inc.
Safety for Industrial Control Equipment.
– ISA 12.12.01 – Nonincendive Electrical
Equipment for Use in Class I and II, Divisi-
on 2 and Class III, Divisions 1 and 2 Hazar-
dous (Classified) Locations.
– UL 60950 – Safety for Information
Technology Equipment.
– Germanischer Lloyd – rules for classifica-
tion and construction VI-7-3 part 1.
Certified devices are marked with a
certification identifier.
Notes on CE
7
identification
The devices comply with the regula-
tions of the following European
directives:
2004/108/EC (EMV)
Directive of the European Parlia-
ment and of the Council on the
approximation of the laws of the
Member States relating to electro-
magnetic compatibility.
2011/65/EU (RoHS)
Directive of the European Parlia-
ment and of the Council on the
restriction of the use of certain
hazardous substances in electrical
and electronic equipment.
The EU declaration of conformity is
kept available for the responsible
authorities in accordance with the
above-mentioned EU directives at:
Hirschmann
Automation and Control GmbH
Stuttgarter Straße 45-51
D-72654 Neckartenzlingen
Telephone: +49 (0)1805 14-1538
The product can be used in the indu-
strial sphere.
– Interference immunity:
EN 61000-6-2
– Radio interference level:
EN 55022 Class A
Warning!
z
This is a Class A device. This equip-
ment may cause radio interference if
used in a residential area; in this
case it is the operator s responsibili-
ty to take appropriate measures.
The precondition for compliance
with EMC limit values is strict adhe-
rence to the construction guidelines
specified in this description and
operating instructions.
FCC Note:
This equipment has been tested and found
to comply with the limits for a Class A digi-
tal device, persuant to part 15 of the FCC
Rules. These limits are designed to provide
reasonable protection against harmful inter-
ference when the equipment is operated in
a commercial environment. This equipment
generates, uses, and can radiate radio fre-
quency energy and, if not installed and
used in accordance with the instruction
manual, may cause harmful interference to
radio communications. Operation of this
equipment in a residential area is likely to
cause harmful interference in which case
the user will be required to correct the inter-
ference at his own expense.
Recycling Note:
,
After its use, this product has to be
processed as electronic scrap and
disposed of according to the prevai-
ling waste disposal regulations of
your community / district / country /
state.