Duratech DURAPRO-17 Посібник - Сторінка 4

Переглянути онлайн або завантажити pdf Посібник для Тепловий насос Duratech DURAPRO-17. Duratech DURAPRO-17 14 сторінок.

Duratech DURAPRO-17 Посібник

2.2 Dimensions

2.2 Dimensions
DURAPRO-12/ 17/ 21 / 25S / 28TS
DURAPRO-12/ 17/ 21R32
Water outlet
3
4
Water inlet
5
2
DURAPRO-25R32/ 28TR32
UNIT
1
2
3
DURAPRO-12
1003
396
767
DURAPRO-17
1046
435
768
DURAPRO-21
1161
470
863
DURAPRO-25S
1160
490
862
DURAPRO-28TS
1160
490
862
Water outlet
* All dimensions in mm
4
Water inlet
5
2
Model
1
2
3
DURAPRO-12R32
1000
418
605
DURAPRO-17R32
1046
435
768
DURAPRO-21R32
1161
470
863
DURAPRO-25R32
1161
470
1274
DURAPRO-28TR32
1161
470
1274
6
1
6
Water
4
5
6
outlet
350
97
545
50
1
350
100
615
50
465
97
790
50
465
97
790
50
465
97
790
50
3
6
unit mm
water outlet
water inlet
4
5
6
350
97
545
φ50
φ50
350
100
615
φ50
φ50
465
97
790
φ50
φ50
550
97
775
φ50
φ50
550
97
775
φ50
φ50

3. Installation and Connection

3.1 Heat Pump Location

The unit will perform well in any outdoor location provided that the following three factors are
presented:
1. Fresh Air - 2. Electricity - 3. Pool filter piping
The unit may be installed virtually anywhere outdoors. For indoor pools please consult the
supplier. Unlike a gas heater, it has no draft or pilot light problem in a windy area.
DO NOT place the unit in an enclosed area with a limited air volume, where the units
discharge air will be re-circulated.
DO NOT place the unit to shrubs which can block air inlet. These locations deny the unit of a
continuous source of fresh air which reduces its efficiency and may prevent adequate heat
delivery.
Water
inlet
50
50
50
50
50

3.2 How Close To Your Pool?

Normally, the pool heat pump is installed within 7.5 meters of the pool. The longer the distance
from the pool, the greater the heat loss from the piping. For the most part ,the piping is buried.
Therefore, the heat loss is minimal for runs of up to15 meters(15 meters to and from the pump =
30 meters total), unless the ground is wet or the water table is high. A very rough estimate of heat
loss per 30 meters is 0.6 kW-hour,(2000BTU) for every 5°C difference in temperature between the
pool water and the ground surrounding the pipe, which translates to about 3% to 5% increase in
run time.
6
7