REMOVING MODULES FROM THE MOD HUB
Before removing the modules from the MOD HUB, turn the unit off by
depressing the power switch located on the front panel of the MOD HUB.
Unplug the power cord from the wall outlet. Disconnect the cables from
the connectors on the module that is being removed.
Dislodging Modules From The MOD HUB
Loosen the module from the MOD HUB unit by unscrewing both of the
captive screws with your fingers. The captive screws are located on each
end of the module. Loosen the captive screws until they are unthreaded to
the point where they hang freely from the module.
With your fingers, grasp each of the module's captive screws and pull the
module out of the MOD HUB unit until it is free from the unit. (If you are
removing a blank panel, simply unscrew the two fasteners.)
INSTALLING MODULES INTO THE MOD HUB
Before installing modules into the MOD HUB, turn the unit off by
depressing the power switch located on the front panel of the MOD HUB.
Unplug the power cord from the wall outlet.
Loading Modules into the MOD HUB
Remove any blank panels or modules being replaced from the MOD HUB.
Unpackage the module to be installed, taking care not to harm the module.
Grasp the module by the faceplate (with its circuitry facing left) and gently
place the module into the empty slot on the MOD HUB. Push the module
into the MOD HUB (some force may be needed to seat the module into
position) until the module's face plate is seated against the unit.
Tighten the captive screws on the module with your fingers and fasten
them in the locking position. Attach the cables running from each device
in the ARCNET LAN to the appropriate module connectors on the newly-
installed expansion module. Refer to the MOD HUB Series User Manual,
Chapter 2, to test the module for proper working operation.