DuraWatt DSATX 220 Посібник користувача - Сторінка 10

Переглянути онлайн або завантажити pdf Посібник користувача для Джерело живлення DuraWatt DSATX 220. DuraWatt DSATX 220 13 сторінок. 220-watt dc-dc atx power supply

4.6.

Advanced Features

For some users enough is never enough. The DSATX has the ability to fine tune many of the parameters
that control its behavior. By using Set and Get commands ('S' and 'G') it is possible to read and write these
parameters to the DSATX. To use the Set command, type at the prompt, an 'S' followed by 2 numbers for the
index, followed by either 4 numbers or 1 number for the value.
Ex:
>S011130 ß Set parameter 1 (LOWVOLTS) to 11.30V
To use the Get command type 'G' at the prompt followed by the 2 number index.
Ex:
ß Get parameter 90 (Program Memory Version)
>G90
ß Returns this result (1.08)
0108
4.7.

Advanced Feature Tables

The following tables show the available Parameter settings and Queries. Parameters will respond to the
Set and Get command. Queries will only respond to the Get command.
Parameter
Index
LOWVOLTS
01
VINHIGHTHRESH
02
HIGHVOLTS
03
VOLTSHYST
04
VOLTSTHYST
05
VOLTSTHYST1
06
TURNONDELAY
07
PULSEWIDTH
08
MAXTIMER1
09
TIMER1EE
10
TIMETOKILL
11
USEPOTS
12
ENABLESLEEP
13
FEEDON
14
VTURNON
15
ACCTIMEVAL
16
TEMPHIGH
17
TEMPLOW
18
TEMPHYST
19
TEMPLOWSIGN
20
TEMPTHYST
21
ENABLE5VSBOFF
22
ENABLESHUTDOWN
23
MASTERMODE
24
EARLYAUXCUT
25
Query
Index
PlusVIN
40
Plus12
41
Plus5
42
Plus3_3
43
ActualTemp
44
TempSign
45
LowVoltThresh
46
CountDownTimerVal
47
CurrentState
48
MainCounter
49
P_VERSION
90
E_VERSION
91
DSATX Manual
Factory
Default
Units
Value
1100
10mV
Hard Coded Vin Low Battery Threshold (if USEPOTS =0)
1300
10mV
Alternator "Turn on" Voltage Threshold
1650
10mV
Vin Over Voltage Threshold
0045
10mV
Vin Voltage Hysteresis (Engine Cranking)
1000
10ms
Vin Voltage High to Low Time Window (Engine Cranking)
0100
10ms
Vin Voltage Low to High Time Window
0100
10ms
Time To Wait After ACC High before sending turn on pulse
0100
10ms
Motherboard Power Switch Press Duration
1200
1s
Maximum CountDown Time set by Potentiometer P1
1200
1s
Hard Coded CountDown Time (if USEPOTS =0)
0090
1s
Time Allowed for Computer to Shut Down
1
1=yes, 0=no If set, P1 and P2 set CountDown Time and Vin Low Battery Threshold
1
1=yes, 0=no If set, Unit Will go use Sleep Mode, ACC High for Wake Up
1
1=yes, 0=no If set, Serial Port Diagnostic Status Feed is Enabled
0
1=yes, 0=no If set, Mb Switch Press occurs after Vin is above VINHIGHTHRESH
0050
10ms
Settling time for the ACC input (Debouncing time)
0550
0.1 deg C
Maximum Operating Temperature
0100
0.1 deg C
Minimum Operating Temperature (Can be Positive or Negative)
0050
0.1 deg C
Temperature Stabilization Margin (Hysteresis to Prevent Oscillations)
0
1=pos, 0=neg Polarity of TEMPLOW (Minimum Operating Temperature)
0200
10ms
Temperature Time Stabilization Window (Temp must stay good/bad)
1
1=yes, 0=no Allows +5VSB Rail to Turn Off to Save Battery Life
1
1=yes, 0=no Allows unit to Send the Motherboard Switch Press for Shutdown
0
1=yes, 0=no Allows DSATX to be cascaded with 2 or more DSATX for more Power
0
1=yes, 0=no AUX will go away as soon as shutdown pulse is sent
Units
N/A
10mV
The Current Voltage at the VIN terminal
N/A
10mV
The Current Voltage on the 5V Rail
N/A
10mV
The Current Voltage on the 12V Rail
N/A
10mV
The Current Voltage on the 3.3V Rail
N/A
0.1 deg C
The Current Temperature
N/A
1=pos, 0=neg The Current Temperature Polarity
Current VIN Low Voltage Threshold (hardcoded or set by P2 between 10-12
N/A
10mV
volts)
Current CountDown Timer Value (hardcoded or set by P1 between 0 and
N/A
1s
MAXTIMER1)
Current State: 0 = Wakeup, 1 = Startup, 2 = Running, 3 = Count Down, 4 Shut
N/A
N/A
Down, 5 Sleep, 6 Bad Temp
N/A
1s
Current Value of Counter used when Counting Down to Swtich States
N/A
N/A
Flash Memory Version Number
N/A
N/A
EEPROM Memory Version Number
Copyright 2006 Mpegbox.com
Description
Discription
Page 10 of 13
Set By 'P' in
Extended
Basic Mode
Y
Y
Y
Y
Y