AddSecure Edge VS5051 Посібник користувача - Сторінка 9

Переглянути онлайн або завантажити pdf Посібник користувача для Система безпеки AddSecure Edge VS5051. AddSecure Edge VS5051 14 сторінок. Connect intercom
Також для AddSecure Edge VS5051: Посібник користувача (10 сторінок)

AddSecure Edge VS5051 Посібник користувача
LED
Panel
Power
Cellular
Ethernet
System

9 Configuration of the voice panels

10 Commissioning test

PDK-13010-v.6.0 Edge VS5010 and VS5051 User manual
The Edge terminal provides extensive feedback via its LED indicators, which
have a flash range from 1 to 5 as shown in the table below. These are used
to report status locally and to allow the installer to install the terminal
correctly so it can signal to the AddSecure Connect platform.
OFF
Flicker on
100/0
(Trouble)
No panel
Panel fault
(or not
(check call
enabled)
overdue)
No battery
fitted
Battery fault
(or not
enabled)
No
connection
SIM card
(or not
registered
enabled)
No
connection
Local
(or not
connection
enabled)
No power
For details about the configuration of specific voice panels and alarms,
please refer to the relevant manufacturer's documentation on their
websites.
Note: Voice panels shall be installed in accordance with EU directive
2014/33 and with EN81 regulations.
VS5010 terminals do not require manual programming when sited in an
elevator environment. All required information for configuration will have
been provided when the AddSecure Subscription Application webform was
completed. To ensure settings have been correctly downloaded please
check the status of the LEDs on the lid of the terminal enclosure.
LEDs
Panel
ON
Power
ON (Short blip shows charging ok)
Cellular Path
ON (Short blips when sending Data)
Ethernet Path
OFF (Not Enabled)
System
ON
If LEDs do not have these states after installation, please contact your local
AddSecure Support team for assistance.
Flashing
On
50/50
90/10
0
(Trouble)
(Good)
Panel OK,
Panel OK,
SIP test fault
SIP test OK
Battery low
(limited run
Battery OK
time)
Internet
Cellular
accessible
polling
Internet
Ethernet OK
accessible
System fault
System OK
Meaning
Flicker off
10/90
0/100
(Good)
Panel and sip
test OK,
Dial port activity
Battery OK,
charging if
power,
discharging if no
power
Polling OK,
data activity
Polling OK,
data activity
page 9