Safety Instructions
G
Mains supply must be switched off before any electrical connections or maintenance is
carried out.
G
lnstallation must be supervised by a competent electrician.
G
This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for
their safety.
G
Children should be supervised to ensure that they do not play with the appliance.
G
Avoid the back-flow of gases into the room from the open flue of gas or other open-fire
appliances when mounted in outside windows or walls.
Installation
Before Installation
G
For best results this fan should be fitted as high on the wall as possible, or on the ceiling.
G
DO NOT install the fan within a shower cubicle.
G
This fan is double insulated and does not require an earth.
G
When installing fan through an external wall, an external wall grille must be fitted .
Installation
G
Cut a suitable diameter hole. Recommended size is Ø115mm (with or without board fixing
clips). lf the fan is to be fixed in the ceiling ensure that the hole is between the joists.
G
Remove the cover from the fan by twisting the front cover anti-clockwise.
G
Hold the body of the fan against the wall or ceiling and mark the four screw holes and the cable
entry on the side. Use the fixing clips to secure the fan in panel walls and ceilings – see figure 1a.
IMPORTANT: Ensure that the fan is square on wall or ceiling.
G
Bring the power cable into position, as marked. Allow an extra 230mm (9") protruding to
facilitate connection.
Wiring
NOTE: All wiring must be fixed securely and the cable to the fan should be a minimum of 1mm
in section. All wiring must comply with current lEE Regulations. lf in any doubt contact a qualified
electrician.
Electrical Connection: Standard Model – see Figure 1.
Remove the internal cover by removing the 2 small caps and retaining crosshead screws to
access the terminal connections.
The fan can either be operated from a separate pullcord switch fitted to the ceiling of the
room or can be connected to the light switch so that the fan will start when the light is
switched on. A double pole fused spur having a contact separation of at least 3mm in all
poles must be used and fitted with a 3 amp fuse, and should be sited outside any room
containing a shower or fixed bath. The fan should not be accessible to a person using either
the shower or the bath.
14:17
Page 2
2
2
Figure 1
Electrical connection: Standard model
Top View
Electrical Connections: Timer model – see Figure 2.
Remove the internal cover by removing the 2 small caps and retaining crosshead screws to
access the terminal connections. The fan can either be operated from a separate pullcord
switch fitted to the ceiling of the room or can be connected to the light switch so that the fan
will start when the light is switched on. A double pole fused spur having a contact separation
of at least 3mm in all poles must be used and fitted with a 3 Amp fuse, and should be sited
outside any room containing a shower or fixed bath. The fan should not be accessible to a
person using either the shower or the bath. See overleaf for timer adjustment instructions.
Figure 2
Electrical connection: Timer model
Top View
3
Figure 1a
Side View