Elsat iNode Інструкція з експлуатації - Сторінка 10

Переглянути онлайн або завантажити pdf Інструкція з експлуатації для Вимірювальні прилади Elsat iNode. Elsat iNode 15 сторінок. Serial transceiver usb

iNode Serial Transceiver USB – instruction manual
AD - RSSI[i] = 0xAD -> RSSI = -83dBm (signed integer); Range: -127 < N < +20
dBm; 127 RSSI is not available
HCI frame with BLE scan result (response for an active scan):
043E1A02010400A35F356F12000E0D09694E6F64652D333535464133AF
043E1A
04 - HCI packet indicator: 0x04 EVENT (Core_V4.0.pdf: Volume 2 Part E, Section 5.4)
3E - event_code = 0x3e -> LE EVENTS
1A - HCI parameter total length -> 0x1A = 26
02010400A35F356F12000E0D09694E6F64652D333535464133AF - event_parameters:
02 - Subevent_Code = 0x02 -> LE Advertising Report event
01 - Num_Reports = 0x01 -> number of responses in event (always 1)
04 - Event_Type[i] = 0x04 -> scan response (SCAN_RSP)
00 - Address_Type[i] = 0x00 -> public device address
A35F356F1200 - Address[i] = 0x00126F355FA3 (Public Device Address)
0E - Length_Data[i] = 0x0E = 14 (length of the Data[i] field)
0D09694E6F64652D333535464133 - Data[i] -> Length_Data[i] octets of advertising or
scan response data formatted as defined in Core_V4.0.pdf: Volume 3 Part C, Section 8.
https://www.bluetooth.org/en-us/specification/assigned-numbers/generic-access-profile
0D - 0x0D -> Length = 0x0D
09694E6F64652D333535464133 -> Data
AF - RSSI[i] = 0xAF -> RSSI = -81dBm (signed integer); Range: -127 < N < +20 dBm; 127
RSSI is not available
BLE advertisement frame:
02010619FF1293011000001700AB18951F485435BE5B809D6F571E40E8
020106
02 -> data length: 2 bytes
0106 -> data
01 -> 0x01 -> EIR Data Type = 0x01 -> «Flags»
06 -> 0x06 -> EIR Data = 0x06 -> LE General Discoverable Mode (bit 1), BR/EDR
Not Supported (bit 2)
19FF1293011000001700AB18951F485435BE5B809D6F571E40E8
19 -> data length: 25 bytes
FF1293011000001700AB18951F485435BE5B809D6F571E40E8 -> data (25 bytes)
FF -> 0xFF -> EIR Data Type = 0xFF «Manufacturer Specific Data»
1293011000001700AB18951F485435BE5B809D6F571E40E8->
1293 -> 0x9312 -> 0x93XX identifier of iNodeCareSensor #3; 0xXX1X
0110 -> 0x1001 type -> bit 15 to bit 12 -> reserved, bit 11 to bit 0 -> group
0000 -> 0x0000 flags ->
09 - EIR Data Type = 0x09 -> «Complete Local Name»
694E6F64652D333535464133 – iNode-355FA3
version 1; 0xXXX2 24 h elapsed from the last readout;
SENSOR_ALARM_MOVE_ACCELEROMETER=1,
SENSOR_ALARM_LEVEL_ACCELEROMETER=2,
SENSOR_ALARM_LEVEL_TEMPERATURE=4,
SENSOR_ALARM_LEVEL_HUMIDITY=8,
ELSAT s.c.