Elsema Intelligent Swing iS330 Посібник користувача - Сторінка 6

Переглянути онлайн або завантажити pdf Посібник користувача для Відкривач воріт Elsema Intelligent Swing iS330. Elsema Intelligent Swing iS330 15 сторінок. Hydraulic swing gate opener

Elsema Intelligent Swing iS330 Посібник користувача
C. INSTALLATION
1) Check that the motor mounting position on the gate pillar can be done with the measurements
in Table 1 and Graph 1.
2) Fix the pillar support as shown in (Fig.1 Page5) shortening or extending the support according
to the dimensions A and B shown in the (Table1 Page 3). The support should be fixed at a
height where the gate has a sufficiently rigid surface to fix the gate support, bearing in mind
that the gate support will be fixed 15 mm lower than the pillar support. (Fig.1 Page 10).
3) Shorten or lengthen the gate support according to the dimensions for C shown in the table on
page 3. Connect the iS330 opener to the gate support, with the rod completely extended
(Fig.2 Page 5) and with the swivel joint nut fully tightened (Fig.3 Page 5). Once this has been
done use a spirit level (Fig.4 Page 5) to mark the position of the gate support on the gate.
Dismantle the gate support and fix it to the gate using the markings previously made.
4) Mount the motor and unscrew the swivel joint nut three
turns to ensure closure. Attach the security ring and the
safety bolt supplied.(Fig.3 Page 5).
5) Electrical connections: Unscrew the end cover and connect
the terminals according to the following diagram
6) Open the door manually to the desired open position, slide
the collar stopper along the arm (Fig.9 Page 5) up to the
front cover plate, fixing its position with the Allen key. The hydraulic transmission can then be
plugged in and started. Re-position the collar stopper to achieve the desired opening position.
7) The force of the motors can be adjusted by adjusting the red and the blue valves located on
the top side of the motor. Remove the arm cover to expose these valves (Fig.10 Page 5). The
force valves are independent in opening (blue valve) and closing (red valve). The screws can
be adjusted by turning them a maximum of 45º and should be adjusted slightly above the
minimum, in this way the force of the hydraulic system is reduced thus increasing safety.
8) The aluminium arm cover can then be placed back into position (Fig.11 Page 5), followed by
its plastic cover and the end cover.
 
iS330/iS330D SWING GATE OPENER MANUAL