Accessories:
Name
C-BOX 100/200
C-BOX 300/310
GFC-41
OM4000
INT-24
Electrical Connections:
DS4600A is equipped with a cable terminated by a 25-pin female D-sub connector for connection to the power
supply and input/output signals.
Do not connect GND and SGNDs to different (external) ground references. GND and
SGNDs are internally connected through filtering circuitry which can be permanently
damaged if subjected to voltage drops over 0.8 Vdc.
CAUTION
The details of the connector pins are indicated in the following table:
Pin
Name
13
VS
25
GND
1
CHASSIS
9
VS
18
EXT TRIG+
19
EXT TRIG-
6
IN1+
10
IN1-
14
IN2+
15
IN2-
8
OUT1 +
22
OUT1-
11
OUT2 +
12
OUT2-
20
RXAUX
21
TXAUX
23
SGND Aux
24
GND
16
Reserved
17
Reserved
Pin
RS232
2
TX232
3
RX232
4
RTS232
5
CTS232
7
SGND Main
Description
Connection Box
Connection Box Profibus
90° Reading Device
Oscillating Mirror
20 mA Current Loop Interface Board
25-pin D-sub female connector pinout
Function
Power supply input voltage +
Power supply input voltage -
Chassis Ground
External Trigger supply voltage +
External Trigger +
External Trigger -
Input 1 +
Input 1 -
Input 2 +
Input 2 -
Output 1 +
Output 1 -
Output 2 +
Output 2 -
Auxiliary RS232
Auxiliary RS232
Signal Ground Auxiliary interface
Power Supply Voltage -
RS485
Full-Duplex
TX485+
RX485+
TX485-
RX485-
SGND Main
DS4600A QUICK GUIDE
Part Number
93ACC1510, 93ACC1520
93A301000, 93A301030
91D081000
93A251030
93A151000
25-pin female connector
RS485
Half-Duplex
RTX485+
RTX485-
SGND Main
20 mA C.L.
(INT-24 Only)
CLOUT-
CLIN-
SGND Main