DUSS DIA 303 S Інструкція з експлуатації - Сторінка 4
Переглянути онлайн або завантажити pdf Інструкція з експлуатації для Дриль. DUSS DIA 303 S. DUSS DIA 303 S 4 сторінки. Diamond core drill
wiring or its own cord.
Cutting accessory contacting a „live" wire may make exposed metal
parts of the power tool „live" and could give the operator an electric
shock.
Take protective measures when dust can develop during working
that is harmful to one's health, combustible or explosive.
Some dusts are regarded as carcinogenic. Wear a breathing mask and
work with dust extraction.
Do not expose power tool to rain or splash water.
Stop working immediately if water is entering the power tool and have
the power tool checked by a qualified electrician. Otherwise the life of
the user may be at risk.
• Before starting drilling work, check that the core bit is correctly
seated on the chuck or, when working with an extension, that the
extension is firmly seated on the drill spindle and the core bit on the
extension.
• Ensure that the drilling does not affect the statics of the building.
• The area around the drilling must be devoid of any electricity cables,
gas, water or other pipes. Any cable or pipes in the area around the
drilling must be disconnected.
• Special safety precautions must be taken for drillings in walls where
the drill stand is fixed by vacuum.
• Ensure that if the drill core drops out, especially in the case of ceiling
breakthroughs, nobody will be injured or damage can occur. If
necessary, install a collecting device and close off the front and rear
drilling area.
• Have the cord and the plug exchanged exclusively by DUSS or a
DUSS customer service.
• Only use DUSS diamond core bits with drilling dia. 52 - 250 mm.
Noise and vibration information
(in accordance with EN 62841)
Typical A-weighted noise levels of the DIA 303 S diamond core
drilling in sand-lime brick, drilling dia. 102 mm:
Noise pressure level:
L
Noise power level:
L
Uncertainty:
K
Wear ear protection.
Vibration data for the DIA 303 S diamond core drilling in sand-lime
brick, drilling dia. 102 mm:
Normal setting:
a
Uncertainty:
K = 1.5 m/s²
Compressor setting:
a
Uncertainty:
K = 1.5 m/s²
Typical A-weighted noise levels of the DIA 303 S diamond core
drilling with impact in concrete, drilling dia. 82 mm:
Noise pressure level:
L
Noise power level:
L
Uncertainty:
K
Wear ear protection.
Vibration data for the DIA 303 S diamond core drilling with impact
in concrete, drilling dia. 82 mm:
Normal setting:
a
Uncertainty:
K = 1.5 m/s²
Compressor setting:
a
Uncertainty:
K = 1.5 m/s²
The values given in this instruction have been measured in accordance
with EN 62841 standardised measurement methods and may be used
for comparing power tools with each other. They also may be used
for a preliminary assessment of exposure and represent the main
4
= 97 dB (A)
pA
= 108 dB (A)
WA
= K
= 4 dB
pA
WA
= 2.3 m/s²
h,DD
= 3.1 m/s²
h,DD
= 99 dB (A)
pA
= 110 dB (A)
WA
= K
= 3 dB
pA
WA
= 14.4 m/s²
h,ID
= 15.0 m/s²
h,ID
Translation of the DIA 303 S original operating instructions
applications of the power tool. However, if the power tool is used for
other applications or with other accessories or if it is poorly maintained,
the values may differ. This may increase the exposure level over the
entire working period.
For an accurate estimation of the exposure level, the times when the
power tool is switched off or when it is running but not actually in use
should be taken into account. This may reduce the exposure level
over the entire working period. Wear ear protection and take additional
safety measures to protect the operator from the effects of vibration
such as: maintain of the power tool and the accessories, keeping
hands warm, organization of work patterns.
Declaration of Conformity
We declare in our sole responsibility that the DIA 303 S diamond core
drill conforms to the following standards or standardisation documents:
EN 62841-1, EN 62841-2-1, EN 55014-1, EN 55014-2, EN 61000-3-2,
EN 61000-3-3 as per the provisions laid down in Directive 2006/42/EG,
2014/30/EU, 2011/65/EU
The technical documentation is archived at the manufacturer.
FRIEDRICH DUSS
Maschinenfabrik GmbH & Co. KG
75387 Neubulach, Germany
Konrad Duss
General Manager
08/2020
www.duss.de