Dust Free DFHPA Посібник з монтажу та експлуатації - Сторінка 4
Переглянути онлайн або завантажити pdf Посібник з монтажу та експлуатації для Очищувач повітря Dust Free DFHPA. Dust Free DFHPA 12 сторінок. Bypass hepa /bypass hepa plus air cleaner
DUST FREE
BYPASS HEPA / BYPASS HEPA PLUS INSTALLATION & OPERATION MANUAL
®
INSTALLATION NOTES
The unit is a versatile appliance with
multiple installation configurations. It is
recommended to take your time in planning
the installation.
• Return to return integrated with the forced
air heating/cooling system.
• Central draw points using dedicated duct
system
• Consult the manufacturer for other special
applications.
SUGGESTED MEDIA AND LAMP REPLACEMENT
• UV-C lamp - 1year
• Pre/Carbon filter - 6-12 months
• HEPA filter - 1-3 years
• PCO filter - 2-3 years
WARNING
Electric Shock Hazard.
Can cause injury or death.
Electrical wiring of the unit to the
HVAC system should be done by a
licensed HVAC technician or
electrical installer.
WARNING
UV Light Hazard.
Can cause serious eye and skin
damage.
Do not look at UV-C light. Wear UV-C
eye and skin protection
• Verify clearance on the ductwork to
mount the unit using the Forced Air
heating/ cooling system. See Appendix A.
• Minimum clearance requirements for
maintenance and service. Allow at least
18" for filter removal.
• Interaction between the unit and other
mechanical devices.
• Prior to installing, serious consideration
must be taken to ensure this filtration
system will operate properly if integrated
to any other type of mechanical system,
i.e. a forced air system, or an air handling
unit. To insure proper operation &
compatibilities of both system, it is
required that you follow the instructions in
this manual.
• UV unit #19851 is designed to emit
powerful ultraviolet radiation. It is
dangerous to come in contact with or
look at the light from this unit. Always turn
the air cleaner OFF and UNPLUG the unit
before opening panels or the filter access
door.
• Do not obstruct or cover the air intake
or air outlet of the filtration system. An
approximate 4" opening will need to be
cut into the existing duct work to install
the device properly.
• Vertical or horizontal mounting is
permissible.
NOTICE
Qualified Technicians Only.
This device is for residential
applications only and must be
installed in compliance with all
national and local electrical and
mechanical codes. Failure to do so
will void Dust Free® Warranty.