BIO-FIGHTER® 4XTREME INSTALLATION & OPERATION MANUAL
IF THE LAMP DOES NOT ILLUMINATE
• Check that the lamp connector is securely
attached to lamp.
• Check that the fuse is in good working
order. Replace if necessary.
• Check that electrical service is operating.
LAMP REPLACEMENT(Annually)
The lamp should be replaced annually even if
it appears to be operating normally. UV-C
energy production diminishes over time.
1. Obtain the correct replacement lamp for
your model.
2. Disconnect electrical service
3. Open the cover of the device. Allow lamp
to cool 10 minutes before touching.
4. Disconnect the electrical connector to the
lamp.
5. Unscrew the two knurled nuts of the lamp
retaining bracket and slide the bracket
away from the lamp retaining lip.
6. Carefully remove the UV-C lamp and
replace it with the new lamp. Be sure to
clean the lamp of dust and fingerprints
prior to installation.
7. Slide the retaining bracket back in place
and tighten knurled nuts.
8. Reconnect electrical connector to the lamp.
9. Close the cover.
10. Reconnect electrical service.
WARNING
Burn Hazard.
During replacement, allow lamps to cool 10 minutes
before removing them. Personal injury may result.
WARNING
Mercury Hazard. Do Not Break.
Each UV-C lamp contains a small amount of Mercury.
May cause redness or irritation. Use proper disposal
techniques in case of breakage.

FUSE REPLACEMENT

1. Disconnect electrical service.
2. Open cover.
3. Remove fuse from fuseholder.
4. Install new fuse. Only use a 250V/3 amp
fuse.
5. Close cover.
6. Reconnect electrical service.
LAMP DISPOSAL
Dispose of your spent UV-C lamps at your
local recycling center. You may also send your
spent lamps in the same container you
received your replacement lamps to:
Dust Free® Lamp Reclamation
1112 Industrial Drive
Royse City, TX 75189
PROPER CLEAN-UP TECHNIQUE IN CASE OF
LAMP BREAKAGE
Wear protective gloves, eyewear and mask.
Sweep the broken glass and debris into a plastic
bag, seal the bag, and dispose of properly.
Contact your local waste management office for
proper disposal.
Do not use a vacuum cleaner. Do not
incinerate.
Replacement Parts
UV-C Lamp - 21"
UV-C Lamp - 33"
UV-C Lamp - 45"
Ballast - Multi-voltage
Cover Interlock Switch
Slide Bracket Springs (2)
Slide Bracket
Knurled Nuts (2)
Fuseholder
Fuse
For information on the dealer in your area call: 1-972-635-9564.
Visit us at http://www.dustfree.com
7
Part No.
06180
06182
06184
06190
212108-00
210-0005-001
212147-00
210226-00
750-0052-001
750-0108-001