Electrical Connections:

DS1100 is equipped with a cable terminated by a 25-pin female D-sub connector for connection with the power
supply and input/output signals.
Do not connect GND and SGND to different (external) ground references. GND and SGND
are internally connected through filtering circuitry which can be permanently damaged if
subjected to voltage drops over 0.8 Vdc.
CAUTION
The details of the connector pins are indicated in the following table:
Pin
9, 13
25*
1*
2, 21
3, 20
4
5
7
8
11
18
19
12, 22
23, 24
6, 10, 14, 15, 16, 17
*
Pins 1 and 25 are connected together internally.

Mechanical Installation:

M3 n°3
4
0.16
7.7
0.3
DS1100-XXX1
25-pin D-sub female connector pinout
Name
Function
VS
Power supply input voltage +
GND
Power supply input voltage -
CHASSIS
Chassis ground
TXAUX
TX RS232 Aux. Interface
RXAUX
RX RS232 Aux. Interface
RTX- RS485 Main Interface
RTX485-
RTX485+
RTX+ RS485 Main Interface
Signal Ground
SGND
Output 1+
OUT 1+
OUT 2+
Output 2+
IN 1-
Input 1-
External Trigger -
EXT TRIG -
GND
Input/Output reference
N.U.
Not Used
N.C.
Not Connected
50
23.8
1.97
0.93
15.4*
0.6
7
0.28
mm
6.9*
inch
0.27
7
0.29
25-pin female connector
9
4.2
20°
mm
* The quote refers to the scan line
DS1100 QUICK GUIDE
90°
23
3