Datalogic S8-PR T53 Series Інструкція з експлуатації
Переглянути онлайн або завантажити pdf Інструкція з експлуатації для Аксесуари Datalogic S8-PR T53 Series. Datalogic S8-PR T53 Series 4 сторінки.
S8-PR...T53
Polarised retroreflex for transparents with threshold
auto-adjustment
INSTRUCTION MANUAL
CONTROLS
OUTPUT LED (yellow)
The yellow LED indicates the output status.
READY LED (green)
The green LED ON indicates normal functioning.
SET PUSH-BUTTON
The acquisition procedure is activated by pressing the SET
push-button.
The control obtained with the SET push-button can be made
externally with the REMOTE input.
LIGHT/DARK TRIMMER
The light/dark mode is selected by a monoturn trimmer.
Please refer to "SETTING" paragraph for the correct use
procedures.
WARNING: the maximum mechanical rotation range of the
trimmer is 240°.Do not force over of the maximum and
minimum positions.
INSTALLATION
The sensor can be positioned by means of
the two housing holes using two screws
(M3x18
or
longer,
0.8Nm
maximum
tightening torque) with washers.
Various orientable fixing brackets to ease
the sensor positioning are available (please
refer to the accessories listed in the general
catalogue).
The operating distance is measured from
the front surface of the sensor optics.
CONNECTIONS
M8 connector
REMOTE
N.O. OUTPUT
(WHITE)
(BLACK)
2
4
1
3
+
-
12...30 Vdc
0V
(BROWN)
(BLUE)
Power supply:
Ripple:
Consumption (output current excluded):
Outputs / Alarm output:
Output current:
Output saturation voltage:
Response time:
Switching frequency:
Emission type:
Operating distance (typical values):
Regulations
LIGHT/DARK selection:
Indicators:
Operating temperature:
Storage temperature:
Dielectric strength:
Insulating resistance:
Ambient light rejection:
Vibrations:
Shock resistance:
Housing material:
Lens material:
Mechanical protection:
Connections:
Weight:
LIGHT/DARK MODE SETTING
Light mode setting
Rotate trimmer in an anti-clockwise direction to
set the LIGHT mode (output ON with the
reflector).
SENSITIVITY ADJUSTMENT
Alignment and sensitivity adjustment
- Position and align the sensor and the reflector on
opposite side at the desired distance.
- Move the sensor vertically and horizontally to
determine the powering on and powering off points
of the yellow LED (OUT) and fix the sensor in the
middle of these two points.
- Press SET push-button until the green READY LED
turns off. The sensor adjusts the sensitivity. If the
READY LED turns permanently ON the acquisition
was successful. If the LED blinks the acquisition
failed due to insufficient contrast. Press SET and
the sensor returns to the previous setting. Verify
alignment between sensor and reflector and the
operative distance before repeating the procedure
from the beginning. If the signal that returns from
the reflector is too high (saturated), the sensor sets
the sensitivity to minimum and functions normally,
however signalling this condition by the READY LED blinking slowly. In this case the sensor
may not detect some transparent objects. You can press SET for 1s to make the READY
LED stop blinking.
Control:
- Enter object laterally in the detection area and
check that the yellow LED turns ON (in dark
mode).
- Remove object and check that the yellow LED
turns OFF immediately (in dark mode).
TECHNICAL DATA
12 ... 30 Vdc
2 Vpp max.
30 mA max
PNP or NPN N.O.; pull up/down resistance = 47 KΩ; 30 Vdc max.
(short-circuit protection)
100 mA (overload protection)
2 V
250 us
2 KHz
RED (660 nm)
2 m (EG2) on R2 reflector
SET push-button
Monoturn trimmer
OUTPUT LED (yellow) / READY LED (green)
-10 ... 55 °C
-20 ... 70 °C
: 1500 Vac 1 min. between electronics and housing
>20 M 500 Vdc between electronics and housing
according to EN 60947-5-2
0.5 mm amplitude, 10 ... 55 Hz frequency, for each axis (EN60068-2-6)
11 ms (30 G) 6 shocks for each axis (EN60068-2-27)
ABS
Window in glass; lens in PC
IP67
M8 4-pole connector
12 g. max. connector version / 50 g. pig-tail version
SETTINGS
Dark mode setting
LIGHT
Rotate trimmer in a clockwise direction to set
the DARK mode (output ON in presence of
the object).
KEYLOCK FUNCTION (keyboard lock)
The KEYLOCK function (keyboard lock) allows to deactivate
the keyboard avoiding accidental changes in the sensor
setting.
If at sensor powering the REMOTE wire is connected to
+Vdc for at least 1 s., the keyboard lock function is activated
and the push-buttons are no longer active.
To deactivate the keyboard lock, the sensor must be turned
off and repowered with the REMOTE wire not connected or
connected to GND.
THRESHOLD AUTO-ADJUSTMENT FUNCTION
The sensor provides threshold auto-adjustment function. If
the received signal decreases/ increases due to dirty optical
lens or reflector, or for cleaning, the sensor automatically
adjusts the commutation threshold to avoid continuous
cleaning of optical parts (after 1 minute of low/high signal). If
the received signal is too low to be adjusted by the sensor
the output turns on and it is necessary to clean the optical
parts.
At sensor powering, if the received signal is a lot higher than
the switching threshold (e.g. after reflector cleaning), the
sensor after 1s automatically adjusts the switching
threshold.
DIMENSIONS
2.6
Receiver
Ø3.2 n°2
M8x1
10
9.25
7
25
OTHER FUNCTIONS
REMOTE input
The REMOTE signal carries-out acquisition functions without
using the SET push-button.
The REMOTE wire connected to +Vdc is equal to pressing the
SET pus-button, connected to GND or not connected is equal
DARK
to not pressing the SET push-button.
Vdc
ACQ.
>1s
REMOTE
GND
Reflector acquisition
Datalogic S.r.l.
Via S. Vitalino 13 - 40012 Calderara di Reno - Italy
Tel: +39 051 3147011 - Fax: +39 051 3147205 - www.datalogic.com
Helpful links at www.datalogic.com: Contact Us, Terms and Conditions, Support.
The warranty period for this product is 36 months. See General Terms and Conditions of Sales for
further details.
Under current Italian and European laws, Datalogic is not obliged to take care of product
disposal at the end of its life. Datalogic recommends disposing of the product in compliance with
local laws or contacting authorised waste collection centres.
© 2008 - 2017 Datalogic S.p.A. and/or its affiliates ALL RIGHTS RESERVED. Without limiting the
rights under copyright, no part of this documentation may be reproduced, stored in or introduced into a
retrieval system, or transmitted in any form or by any means, or for any purpose, without the express
written permission of Datalogic S.p.A. and/or its affiliates. Datalogic and the Datalogic logo are registered
trademarks of Datalogic S.p.A. in many countries, including the U.S.A. and the E.U. All other trademarks
and brands are property of their respective owners. Datalogic reserves the right to make modifications
and improvements without prior notification.
826004105 Rev. E
11
3.5
Emitter
mm