Dataplex OPTO-SPLITTER Посібник - Сторінка 14

Переглянути онлайн або завантажити pdf Посібник для Конвертер мультимедіа Dataplex OPTO-SPLITTER. Dataplex OPTO-SPLITTER 20 сторінок.

RDM / DMX SERIAL LINK
OPTO-SPLITTER 1
8 IDC
X
IDC (Insulation-Displacement Contact) connectors are designed to decrease installation time as they do not
require cable insulation stripping. Instead the connection is formed by pressing the cable onto a sharp contact
blade, which pierces through the insulation and into the conductor core. Depending on the application, cables can
be unterminated on both ends, or have a connector on one end to interface with other equipment (e.g. 5-Pin XLR).
Each Input, Output, and Thru connection point follows the same diagram for common, data positive and data
negative conductors.
1—Insert a small screwdriver into each of the 3 orange tabs on the IDC connector. Using gentle upwards pressure,
push open the tabs to reveal the cable insertion point.
2—Insert unstripped wires into connector per the diagram below and push down the orange tabs. The tabs will
force the cable down onto the blade which will then pierce through the insulation, forming the connection.
3—To connect DMX signal input from an incoming console, use the DMX input in the right corner of the unit. To
pass the DMX signal to another device, use the Thru port.
4—Connect additional cables to each of the eight optically isolated IDC output ports in order to send data to any
DMX device, daisy-chaining between fixtures as necessary.
14
DATAPLEX DEVICES—Opto-Splitters User Manual v1.2—09122020