Datasensor S65-PA-5-Z Інструкція з експлуатації - Сторінка 3

Переглянути онлайн або завантажити pdf Інструкція з експлуатації для Аксесуари Datasensor S65-PA-5-Z. Datasensor S65-PA-5-Z 3 сторінки. Line sensor

OUT
A
M1
M2
Dig1
0
-
This operation is necessary when objects, inside the operating area, must not be detected.
- Detection of the reflecting tape characteristics
- Press contemporily the + and – push-buttons for at least 6s.
- The "TAPE" message appears.
OUT
A
M1
M2
Dig1
t
t
- The reflecting tape characteristics are memorised when the push-buttons are released (the
"TAPE" message blinks for 2s, 4Hz) and the sensor returns to the normal mode.
OUT
A
M1
M2
Dig1
0
This operation is particularly suggested in the "AREA" operating mode as this mode is very sensitive
to the reflecting tape characteristics.
REMOTE FUNCTIONS
KEYLOCK
The keyboard block function is activated at powering on, connecting the SYNC terminal to the
positive power supply (+Vdc) for at least 1 s, and the push-buttons are NO LONGER active.
After the first second, the SYNC input is ready for the normal functioning and if the SYNC is passive
the outputs are deactivated.
To deactivate the keyboard block, the sensor has to be turned off and re-powered maintaining the
SYNC wire not connected or ground connected (GND).
SYNC input
The SYNC signal allows to determine precisely the beginning and end of the identification.
The identification cycle begins after the transition of the SYNC signal from passive to active and the
sensor outputs are updated after max. 8 ms.
All the outputs are deactivated after max. 8 ms from the active – passive transition.
The connection of the SYNC wire to +Vdc corresponds to the passive logic status while SYNC not
connected or connected to 0 V corresponds to the active.
RS485 serial connection (only for S65-PA-5-Z09-xxxZ versions)
The complete sensor remote control is obtained using a RS485 line.
All the functions, such as the threshold selection and functioning modes, can be accessed through
the serial line.
The serial communication parameters are: 9600 baud, non-parity, 8 data bits, 1 stop bit.
All the commands have to be sent via terminal in an ASCII format according to the folllowing
instructions.
- Reading of the sensor status:
At any moment, at the receipt of the 'r <CR> <LF>' command, the sensor configuration is returned.
- Reading of the measurement::
At any moment, at the receipt of the 'v <CR> <LF>' command, the value of the measurement made
by the sensor is returned, in the 'xxxx<CR> <LF>' format (the xxxx are four ASCII characters).
- Remote detection of the thresholds:
To access into the remote detection mode, the SYNC input has to remain passive for at least 300
ms. The commands available are:
@ <CR> <LF>
beginning of the remote setting mode (together with SYNC passive)
threshold selection, with x ∈ {1,2}
cx <CR> <LF>
txxxx <CR> <LF>
threshold value selection, with xxxx ∈ {0..1023}
e <CR> <LF>
memorisation of the configuration sequence.
q <CR> <LF>
exit from the remote setting without saving the configuration.
If the SYNC input is activated before the 'e' (execute) command is given, the sensor exits the
remote setting mode without saving the configuration, similarly to the receipt of the 'q' (quit)
command.
If the SYNC input is active, at the receipt of the @ <CR> <LF> command, the sensor responds
with: ?? <CR> <LF>. At the receipt of the q <CR> <LF> or e <CR> <LF> commands, the sensor
transmits ok <CR> <LF>.
- Remote detection of the operating area:
To access into the remote detection mode, the SYNC input has to remain passive for at least 300
ms. The commands available are:
@ <CR> <LF>
beginning of the remote setting mode (together with SYNC passive)
w <CR> <LF>
acquisition command of the operating area
e <CR> <LF>
memorisation of the configuration sequence.
q <CR> <LF>
exit from the remote setting without saving the configuration.
If the SYNC input is activated before the 'e' (execute) command is given, the sensor exits the
remote setting mode without saving the configuration, similarly to the receipt of the 'q' (quit)
command.
If the SYNC input is active, at the receipt of the @ <CR> <LF> command, the sensor responds
with: ?? <CR> <LF>. At the receipt of the q <CR> <LF> or e <CR> <LF> commands, the sensor
transmits ok <CR> <LF>.
- Remote detection of the reflecting tape characteristics:
To access into the remote detection mode, the SYNC input has to remain passive for at least 300
ms. The commands available are:
@ <CR> <LF>
beginning of the remote setting mode (together with SYNC passive)
u <CR> <LF>
detection command of the reflecting tape characteristics
Dig2
Dig3
Dig4
+
SET
4
5
0
Dig2
Dig3
Dig4
+
SET
A
p
E
A
p
E
Dig2
Dig3
Dig4
+
SET
4
5
0
-
e <CR> <LF>
q <CR> <LF>
If the SYNC input is activated before the 'e' (execute) command is given, the sensor exits the
remote setting mode without saving the configuration, similarly to the receipt of the 'q' (quit)
command.
If the SYNC input is active, at the receipt of the @ <CR> <LF> command, the sensor responds
with: ?? <CR> <LF>. At the receipt of the q <CR> <LF> or e <CR> <LF> commands, the sensor
transmits ok <CR> <LF>.
- Reset of the sensor default configuration:
To access into the remote detection mode, the SYNC input has to remain passive for at least 300
-
ms. The commands available are:
@ <CR> <LF>
z <CR> <LF>
e <CR> <LF>
q <CR> <LF>
If the SYNC input is activated before the 'e' (execute) command is given, the sensor exits the
remote setting mode without saving the configuration, similarly to the receipt of the 'q' (quit)
command.
-
If the SYNC input is active, at the receipt of the @ <CR> <LF> command, the sensor responds
with: ?? <CR> <LF>. At the receipt of the q <CR> <LF> or e <CR> <LF> commands, the sensor
transmits ok <CR> <LF>.
- Operating mode configuration:
To configure the operating mode, the SYNC input has to remain passive for at least 300 ms. The
commands available are:
@ <CR> <LF>
mx <CR> <LF>
e <CR> <LF>
q <CR> <LF>
If the SYNC input is activated before the 'e' (execute) command is given, the sensor exits the
remote setting mode without saving the configuration, similarly to the receipt of the 'q' (quit)
command.
If the SYNC input is active, at the receipt of the @ <CR> <LF> command, the sensor responds
with: ?? <CR> <LF>. At the receipt of the q <CR> <LF> or e <CR> <LF> commands, the sensor
transmits ok <CR> <LF>.
- Delay configuration:
To configure the delay, the SYNC input has to remain passive for at least 300 ms. The commands
available are:
@ <CR> <LF>
dx <CR> <LF>
e <CR> <LF>
q <CR> <LF>
If the SYNC input is activated before the 'e' (execute) command is given, the sensor exits the
remote setting mode without saving the configuration, similarly to the receipt of the 'q' (quit)
command.
If the SYNC input is active, at the receipt of the @ <CR> <LF> command, the sensor responds
with: ?? <CR> <LF>. At the receipt of the q <CR> <LF> or e <CR> <LF> commands, the sensor
transmits ok <CR> <LF>.
NOTE: the single characters have to be distanced amongst themselves at least 1 ms, during
the command transmission.
DECLARATION OF CONFORMITY
We DATASENSOR S.p.A. declare under our sole responsibility that these products are conform to
the 89/336 CEE, 73/23 CEE Directives and successive amendments.
WARRANTY
DATASENSOR S.p.A. warrants its products to be free from defects.
DATASENSOR S.p.A. will repair or replace, free of charge, any product found to be defective during
the warranty period of 36 months from the manufacturing date.
This warranty does not cover damage or liability deriving from the improper application of
DATASENSOR products.
DATASENSOR S.p.A. Via Lavino 265
40050 Monte S. Pietro - Bologna - Italy
Tel: +39 051 6765611
http://www.datasensor.com
DATASENSOR S.p.A. cares for the environment: 100% recycled paper.
DATASENSOR S.p.A. reserves the right to make modifications and improvements without
prior notification.
memorisation of the configuration sequence.
exit from the remote setting without saving the configuration.
beginning of the remote setting mode (together with SYNC passive)
default sensor configuration reset command
memorisation of the configuration sequence.
exit from the remote setting without saving the configuration.
beginning of the remote setting mode (together with SYNC passive)
operating mode selection, with x ∈ {0, 1, 2, 3, 4}
m0 = end object position
m3 = width measurement
m1 = beg object position
m4 = area measurement
m2 = centre position
memorisation of the configuration sequence.
exit from the remote setting without saving the configuration.
beginning of the remote setting mode (together with SYNC passive)
delay selection, with x ∈ {0,1,2,3,4,5}
d0 = 0 ms
d3 = 20 ms
d1 = 5 ms
d4 = 30 ms
d2 = 10 ms
d5 = 40 ms
memorisation of the configuration sequence.
exit from the remote setting without saving the configuration.
DETECTION DIAGRAMS
Fax: +39 051 6759324
826002010 Rev.00