B.

Hose Connections

1.
Connect high pressure hose to machine outlet.
2.
If optional low pressure downstream, in-line
chemical injector is to be used, connect the
injector tube to the detergent inlet and place
the other end of the tube, with the strainer
attached, in the chemical container (not
supplied).
3.
Connect gun/lance assembly to high pressure
hose.
4.
Check inlet water filter is clean then connect
water supply hose to machine. Use a 25mm
(minimum) hose .
Incoming water supply must deliver double the
flow of the machine. If questionable, check
supply at machine. If supply is insufficient, do
not operate from this outlet. For residential use,
the outlet closest to the meter will usually
deliver the highest flow rate. Connect only to
clean town water supply.
Warning: Do not operate from tank or pond.
Doing so will cavitate the pump causing
damage. Cavitation or pump starvation is not
covered
by
warranty.
phenomenon causing vacuum pockets to form
within the pump that eventually implode under
pressure pitting the internal pump surfaces.
Fitting instructions for optional hose reel
1.
Securely clamp the hose reel mounting bar
across the top of the Scud frame using the two
sets of nuts and bolts supplied. Aussie Pumps
recommends using Loctite on the bolts to
prevent them vibrating loose.
Cavitation
is
Aussie Scud & Ultra ... Operator's Instruction Manual
2.
Fit hose reel to the mounting bar using the four
sets of nuts and bolts supplied. Ensure all bolts
are securely tightened and use Loctite to
prevent them vibrating loose. The reel should
be positioned so that it rotates fore/aft to aid
fitting whip hose.
3.
Connect whip hose to high pressure outlet on
pump.
a
4.
Fit handle to reel.
5.
Fit gun to hose using C1500.24 nipple.
6.
Start up machine (see below) and check for
leaks. All leaks must be rectified before using
machine.
C.

Before starting the machine

OPERATE IN WELL VENTILATED AREAS ONLY.
1.
Ensure machine is level
2.
Turn on water supply.
3.
Pull gun trigger until water starts to flow in a
steady steam then release trigger.
Aussie Pumps