The scales must be at standstill. The standstill status symbol must appear at the screen. Press the
ENTER key to send the data to the serial interface.
Note: Printing is not possible if the net weight is 0. The print function only produces one print-out. A reset
is required to print out another copy.
Error Messages
Error Codes
Load cell wires to indicator are
incorrectly connected; or shorted, or
opened; or ADC/ load cell are being
damaged
Weight reading exceeds the zero limit
after switching the scale on.
Weight reading is below the zero limit
after switching the scale on.
Weight reading exceeds load limit.
Weight reading below load limit.
Configuration or Calibration parameters
are not correctly set.
Capacity parameters are not correct.
Calibration error. The incoming signal of
loaded weight is too small, too big,
unstable or un-linear.
Power cord is not properly connected.
Not turn on.
Power outlet not supplying electricity.
Batterie is discharged. Other failure.
Cannot zero the
Load on scale exceeds allowable limits.
display or will
Load on scale is not stable.
not zero when
turned on.
Load cell damage.
No Battery
symbol or
Batteries are discharged.
display of Lo.bAt
M403660-211129-Rev006-UM-e
Description
Solution
Make sure wires are in good order
and condition and correctly
connected. Replace load cell or
ADC chip. Service is required.
Make sure scale platform is empty.
Install platform on scale.
Otherwise the zero calibration/
adjustment have to be done by
authorized personnel.
Reduce load on scale until weight
value can be displayed.
Service by authorized personnel
required.
Contact your local dealer / supplier
for calibration purpose.
Contact your local dealer / supplier
for a new set-up.
Contact your local dealer / supplier
for a new set-up.
Check power cord connections.
Make sure power cord is plugged
into the power outlet. Check power
source. Replace batteries.
Remove load from the scale.
Wait for load to become stable.
Service required.
Charge batteries.
8