Humidity settings
For adjusting the sensitivity of the system to an air supply
which is more humid than the air inside the home. A higher
setting will mean the system reacts more quickly to a humid
air supply then remains off for a period of time and until
the air supply is dry enough to continue ventilating your
home. The DVS® technician sets this function when the
system is installed, however, this setting can be increased or
decreased.
Note: To prevent nuisance stopping and starting
(oversensitivity) the DVS® is programmed to allow some
minor higher air supply humidity readings before it will stop
ventilating. Please call DVS® on 0800 387 387 if you need
assistance and before you adjust these settings.
Humidity settings
Touch settings icon
then –
SETTINGS > HUMIDITY
– Scroll the Humidity sensitivity or Humidity time
CONTROL
up or down to the level you wish -
CO
Sensing & control
2
For enabling or disabling the CO
technician enables this function and pairs the sensor(s)
when the system is installed, however, this function can be
Enabled (turned on) or Disabled (Turned off).
CO
Enable / Disable
2
Touch settings icon
then –
SETTINGS > CO
(touch the Enable/Disable slide switch icon to
> ENABLE
change to Enable or Disable) -
CO
Sensors
2
The DVS® Connect range has one remote plug in CO
as a standard inclusion. Extra sensors can be fitted with a
maximum of four sensors per system. When multiple sensors
are fitted the system uses the average CO
all sensors to activate a higher ventilation rate when the
average CO
concentration rises above 1000ppm.
2
Connecting CO
sensors to the system
2
Plug in the CO
sensor in your room of choice (typically a
2
living room or master bedroom, however any room which
is normally occupied and has a DVS® vent in it will be
fine). Press and hold the pairing button on the front of the
sensor until the green LED light, (this is only visible when
looking through the vent at the bottom of the sensor) is on
continuously. This takes 5 seconds. If the LED light is a little
difficult to see, just hold the button in and count 7 seconds.
For further assistance please call DVS
OK > EXIT
control function. The DVS®
2
CONTROL
2
OK > EXIT
sensor
2
reading across
2
This puts the CO
sensor in pairing mode, which lasts 60
2
seconds.
Then go to the DVS® controller:
a.
Touch the settings icon
UTILITIES > MANAGE CO2 > ADD SENSOR
b.
A box will show, which initially just says Connecting
c.
When the CO
sensor has been found the box shows
2
Success, New CO2 Sensor added
d.
Repeat for additional sensors (up to 4 can be
connected).
Once the sensor(s) has been added, press
preparation for connection is now made.
Note: After Restarting, the system will need approximately
20 minutes to establish proper connections and begin
accurate CO
level readings. A CO
2
appear on the home screen and detailed information will be
available in the diagnostics menu.
If you have more than one sensor, each will need to be
individually paired to the controller rather than pairing them
all at the same time. Select
RESTART
WiFi connection and software upgrades
To check for upgrades or reconnect to your WiFi
Touch the WiFi icon
then choose – WiFi Scan or Check
for upgrades (whichever is applicable) – then follow the
instructions.
Clock
To manually adjust the clock
11:20
Touch the clock numbers
EXIT
Filter change reminder reset
Touch settings icon
then –
SETTINGS > FILTER OPTIONS >
NEW FILTER INSTALLED > YES > EXIT > EXIT
Note: This setting is intended to reset the filter reminder on
your system. Resetting this means that you will receive a
reminder to change your filter again, on the control panel, in
12 months.
on 0800 387 387
®
then –
. The
RESTART
level indicator will
2
when all are connected.
then -
SET DATE AND TIME >
4