MAINTENANCE
Maintenance
Only competent or qualified persons should attempt any service or maintenance of your amplifier. Your AMB Series amplifier will need minimal maintenance. No internal
adjustments need to be made to the unit to maintain optimum performance. To provide years of unhindered operation we suggest a maintenance inspection be carried out
on a regular basis, say every 12 months or so.
Fans
Due to the openness of the air path through your AMB Series amplifier, very
little dust should settle within the amplifier. The unit has been designed so that
any dust and/or foreign particles that do settle within the amplifier will not
unduly hinder the cooling of the amplifier.
The grille in front of the fans will act to limit the amount of dust and lint
entering the amplifier. You will find in time that there will be a build up of dust
and lint on the grille which may start to hinder the airflow through the amplifier.
You should periodically remove the dust and keep the grille clean. Removal of
dust from the rear grille will also aid cooling.
Over time, dust may build up on the leading edge of the fan blades and reduce
their cooling efficiency. The time taken for this to happen will depend on the
environment and the amount of use.
The fan blades are accessible once the lids are removed and can be easily
cleaned. You need only hold the fan rotor still and wipe the dust off the blades.
Many users stall the fan and use compressed air to blow the dust off the fan
blades. It is important to note that the fan blades must be held still whilst
blowing air over the blades otherwise you may burn out the bearings in the fan.
PAGE 10
Fuses
There are four (4) rail fuses provided internally in the unit. These rail fuses are
in series with the positive and negative output supply to each amplifier channel
and provide overall protection for the output stage. If the amplifier is subjected
to heavy use such as short circuits, 1 Ohm or bridged 2 Ohm loads, these fuses
will eventually fatigue and may require replacing to ensure they do not fail at an
inconvenient time.
WARNING: Make sure the unit is off and is unplugged from the
mains. Give the main filter capacitors time to discharge before removing
lids and inspecting the fuses.
You should replace the fuse if the element is sagging or discoloured. Only ever
replace with the same type fuse and current rating.
When checking for a failed fuse, do not rely on visual inspection alone. You
should use an Ohm meter to check continuity
AMB SERIES AUDIO POWER AMPLIFIERS INSTALLATION AND OPERATION MANUAL