Power Output
Maximum Load
Power Bandwidth
Frequency Response
Total Harmonic Distortion
Signal To Noise Ratio
Tone Controls
Bass @ 100Hz: Boost +12dB Cut -12dB; Treble @ 10kHz: Boost +9dB Cut -9dB
Inputs
Input Sensitivity
Mic: 1mV @ 200 Ohms; Aux 1-3: 75mV @ 47K Ohms; Aux 4: 300mV @ 47K Ohms
Outputs
Speaker: 100, 70 Volts, 8 Ohms; Tape: 350mV @ 10K Ohms; Line: Balanced 700mV
Phantom Power
Speaker Zone Selection
Speaker zone selector, switches 100V line output to 6 separate zones.
Controls
1 Master gain control, 6 Speaker zone selector, 1 Speaker "all call" selector,
Pre-announce defeat switch, Phantom Power on/off switch (on rear panel)
Indicators
Power Source
AC 230/240V - 50Hz; DC 24V; 110V - 60Hz (special) 3 pin IEC connector
Power Consumption
Protection
Soft limiter for overload and overdrive protection, plus AC and DC fuses
Dimensions/Weight
Rack Mounting
Tone Generators
Muting
ARCHITECTURAL AND ENGINEERING SPECIFICATIONS
The mixer amplifier shall have four universal input channels, each comprising of a balanced microphone
input with XLR female sockets and an auxiliary input using dual RCA sockets. The 100V line speaker out-
puts should be able to be switched via a six position selector with "all call." A balanced XLR output to
drive additional power amplifiers shall also be provided.
This unit shall offer remote master VCA control, 24V DC and mains power operation, and a vox trig-
gered relay output.
The amplifier master section shall include one master gain control, two EQ controls, one with 12dB of
cut and boost at 100Hz and the other with 9dB of cut and boost at 10kHz. Speaker outputs shall be
transformer isolated at 100V, 70V and 8 ohms. The amplifier must be capable of delivering 60 watts
RMS into an 160 ohm inductive load, with less than 0.5% distortion measured at 1kHz and with system
hum and noise less than -74dB.
The amplifier shall be an Australian Monitor Installation Series model AMIS60.
), 149 Beaconsfield Street, Silverwater, Sydney, NSW, 2128 Australia
ABN 78 001 345 482
-74dB with all controls at their centre position
Four mic/aux universal inputs with XLR female mic sockets and
dual RCA aux sockets plus an insert point
18 Volts DC on all Mic inputs (rear panel on/off switch)
An "all call" switch overrides alI zones.
4 Input channel gain controls, 1 Bass control, 1 Treble control,
88mm H x 480mm W x 330mm D (Chassis Dimensions only). 10kg
Built-in four tone generator module.
Includes Bell, Pre-Announce, Alert and Evac tones
Built-in VOX muting. Channels 1 and 2 will mute channels 3 and 4.
Website: www.australianmonitor.com.au
60 Watts RMS
160 Ohms @ 100 Volts
60Hz - 15kHz < O.5% THD
60Hz - 15kHz (± 3dB)
0.5% @ 1 KHz rated power
Power "on" LED
125 Watts
Standard