SETTINGS
The ICON-3 Paging Station under side provides a single bank of DIP switches for
address selection and future options. The adjustable potentiometer VR1 provides
fi ne adjustment of the microphone audio level.
SW1:
Only two RS485 addresses are valid when using the ICON-3 with Zone
Revolution.
Address 1: Page Station 1
Address 2: Page Station 2
Ensure that each ICON-3 is addressed correctly as per the diagram above.
NOTE: DIP switches 5 & 6 must be in the OFF position when used with Zone
Revolution.
PAGE 6
VR1:
The adjustable trim-pot provides a method to trim the microphone audio gain
to suit the intended application. By default, this level trim is set to a nominal
operating level. Adjustment of VR1 should be performed in conjunction with the
Audio Setup page within the Zone Revolution GUI application, ensuring the level
meters in the associated Input Processing pages are within acceptable limits
and free from clipping under normal and elevated voice levels.