CookTek ISW062 Посібник користувача - Сторінка 10

Переглянути онлайн або завантажити pdf Посібник користувача для Кухонні плити CookTek ISW062. CookTek ISW062 20 сторінок. Induction soup well

In the event of a possible malfunction, your CookTek soup well will display an
error code on the alphanumeric display. Units will beep a specific number of times,
indicated by the error and flash the lights on the control box. Please consult the
following table when encountering an error code. To reset error conditions, remove
the pan from the unit and press the Power button, or unplug the unit.
Error Error Cause
1
Broken temperature
sensor.
2
Broken temperature
sensor. Pan temperature
is too high.
3
Over current (peak).
7
Hardware failure.
8
Zero cross error.
13
User interface error.
16
Critical error.

ERROR CODES

Displayed Message Troubleshooting
E-01
E-02
E-03
E-07
E-08
E-13
E-16
10
Service required.
Remove any pans from
the dry well surface and
let cool. Turn unit off
and on to reset error.
If problem persists,
contact service provider.
Try different cookware.
Service may be
required.
Service required.
Turn unit off, then on.
Plug unit into outlet on
different circuit breaker.
If problem persists,
service is required on
device.
Check control panel
connection, cycle power.
Service required.
Call dealer for service.
Service required.
Manual ISW06x 14161_A USINTL