BENDIX M-40QR Сервісні дані - Сторінка 2

Переглянути онлайн або завантажити pdf Сервісні дані для Блок управління BENDIX M-40QR. BENDIX M-40QR 8 сторінок. Pressure modulator valves

BENDIX M-40QR Сервісні дані

GENERAL SAFETY GUIDELINES

WARNING! PLEASE READ AND
FOLLOW THESE INSTRUCTIONS
TO AVOID PERSONAL INJURY OR DEATH:
When working on or around a vehicle, the following
guidelines should be observed AT ALL TIMES:
▲Park the vehicle on a level surface, apply the parking
brakes and always block the wheels. Always wear personal
protection equipment.
▲Stop the engine and remove the ignition key when working
under or around the vehicle. When working in the engine
compartment, the engine should be shut off and the ignition
key should be removed. Where circumstances require that
the engine be in operation, EXTREME CAUTION should be
used to prevent personal injury resulting from contact with
moving, rotating, leaking, heated or electrically-charged
components.
▲Do not attempt to install, remove, disassemble or
assemble a component until you have read, and thoroughly
understand, the recommended procedures. Use only the
proper tools and observe all precautions pertaining to use
of those tools.
▲If the work is being performed on the vehicle's air brake
system, or any auxiliary pressurized air systems, make
certain to drain the air pressure from all reservoirs before
beginning ANY work on the vehicle. If the vehicle is
equipped with a Bendix
®
DRM
dryer reservoir module, or a Bendix
dryer, be sure to drain the purge reservoir.
▲ Following the vehicle manufacturer's recommended
procedures, deactivate the electrical system in a manner
that safely removes all electrical power from the vehicle.
▲Never exceed manufacturer's recommended pressures.
▲Never connect or disconnect a hose or line containing
pressure; it may whip and/or cause hazardous airborne
dust and dirt particles. Wear eye protection. Slowly open
connections with care, and verify that no pressure is
present. Never remove a component or plug unless you are
certain all system pressure has been depleted.
▲ Use only genuine Bendix
components and kits. Replacement hardware, tubing, hose,
fi ttings, wiring, etc. must be of equivalent size, type and
strength as original equipment and be designed specifi cally
for such applications and systems.
▲Components with stripped threads or damaged parts should
be replaced rather than repaired. Do not attempt repairs
requiring machining or welding unless specifi cally stated
and approved by the vehicle and component manufacturer.
▲Prior to returning the vehicle to service, make certain all
components and systems are restored to their proper
operating condition.
▲ For vehicles with Automatic Traction Control (ATC), the ATC
function must be disabled (ATC indicator lamp should be
ON) prior to performing any vehicle maintenance where
one or more wheels on a drive axle are lifted off the ground
and moving.
▲The power MUST be temporarily disconnected from the
radar sensor whenever any tests USING A DYNAMOMETER
are conducted on a vehicle equipped with a Bendix
Wingman
system.
®
▲You should consult the vehicle manufacturer's operating
and service manuals, and any related literature, in
conjunction with the Guidelines above.
2
AD-IS
air dryer system, a Bendix
®
AD-9si
®
brand replacement parts,
®
The modulator consists of a die cast metal and plastic body
that houses one normally-open solenoid, one normally-
closed solenoid, and an inlet and exhaust diaphragm
valve. A three-pin weather-resistant electrical connector
is an integral part of the modulator solenoid assembly
and delivers the vehicle controller's commands to the
modulator. Two mounting holes are provided for frame or
crossmember mounting of the valve.
The Bendix
M-40QR
®
for the Bendix
Bendix M-40QR modulator has a bias valve to provide an
internal quick-release function.
The supply, delivery, and exhaust ports on the Bendix M-40
modulators have embossed identification codes.
Air Hose
Port ID
Connection
1, SUP
Supply
2, DEL
Delivery
3, EXH
Exhaust
Figure 3 - Port Designation and Function
®
air
®
APPLICATIONS
Bendix M-40
on a vehicle, including ABS and stability interventions. In
applications using these PMVs, an external quick release
valve may also be required, depending on the system
design. Where the modulator is used for individual wheel
control applications, it is typically the last control valve
through which air passes on its way to the service brake
actuator. See Figure 4 for a typical system schematic.
PRESSURE MODULATOR VALVE (PMV) AND
TRACTION CONTROL VALVE (TCV) CHUFF TEST
A wiring harness connects the vehicle modulators to the
controller. The ABS controller is able to simultaneously,
and independently, control the individual modulators.
Bendix
Electronic Control Units (ECUs) perform a Bendix-
®
patented PMV and TCV Chuff Test. The Chuff Test is
an electrical and pneumatic PMV test that can assist
maintenance personnel in verifying proper PMV wiring and
installation. This test is performed only when the vehicle
is stationary (if the vehicle moves, the Chuff Test will not
be performed).
NOTE: If there are any active Diagnostic Trouble Codes
(DTCs), the stop lamp cross-check portion of the Chuff Test
®
will not be carried out until all DTCs are fully diagnosed and
corresponding repairs are successfully conducted. The
ESP/ATC dash indicator lamp ATC/ESP Lamp – a lamp that
indicates when stability functions, including traction control,
modulator is the direct replacement
M-32QR
modulator (See Figure 2). The
®
Function
Air enters from a valve (typically
foot, relay, or quick release).
Air is delivered to the service
actuators.
Air is vented to the atmosphere.
modulators may be used for various purposes