Active Products XE03 Посібник користувача - Сторінка 17
Переглянути онлайн або завантажити pdf Посібник користувача для Мийка високого тиску Active Products XE03. Active Products XE03 19 сторінок.
TROUBLESHOOTING
Disconnect the machine from the power source before making any repairs.
Motor will not start.
Unit does not reach
high pressure.
Output pressure varies high
and low.
Cause
On/Off switch is in the
Power cord is not plugged in.
Extension cord is too long.
Extension cord is not
proper gauge.
Extension cord is damaged.
Electrical outlet does not
supply adequate power.
Tripped pressure washer
circuit breaker
Diameter of garden hose is
too small.
Water supply is restricted.
Not enough water supply.
Water inlet filter is clogged.
Power nozzle is in low-
pressure position.
Pump is sucking air.
Not enough inlet water supply. Turn water on fully. Check
Pump is sucking air.
Water inlet filter is clogged.
16
( | ) position.
Plug in power cord.
Replace extension cord
with either a 25' (7 .6 m)
14AWG cord or a 50' (15 m)
14AWG cord.
Try a different outlet.
Check garden hose for
Open water source fully.
Remove filter and rinse in
warm water.
Turn power nozzle to high-
pressure position.
Check that hoses and
fittings are airtight. Turn
pump by squeezing trigger
water emerges through
the nozzle.
or blockage.
Check that hoses and
fittings are airtight. Turn
pump by squeezing trigger
water emerges through
the nozzle.
Remove filter and rinse
with warm water.