WARNING:
Only qualified and trained operators must install, adjust or use the assembly power tool for non-threaded
mechanical fasteners.
WARNING:
Operator
WARNING:
It is required that eye protection, hearing protection and safety boots be worn at all times while handling this
equipment.
WARNING:
The users or the user's employer must assess specific risks that could be present as a result after each use
based on their application.
● Ensure there is adequate clearance for tool and operator's hands before proceeding. Keep fingers clear of any
moving parts. Keep fingers clear from fasteners and installed materials. Severe personal injury may result.
● Verify
Ensure that there are no electrical cables, gas pipes, etc., which can cause a hazard if damaged by the tool
WARNING:
Do not actuate fastener in the air. Personal injury from fastener ejecting may occur.
WARNING:
Air is exhausted from the bottom of the tool. Direct bottom of the tool (exhausted air) away from operator, other
persons working in the vicinity, foreign matter and liquid.
WARNING:
Do not carry from hoses or use as a hammer.
WARNING:
Do not use in explosive atmosphere.
WARNING:
Ensure air hose is securely connected to avoid possible hose whipping.
WARNING:
Always disconnect air supply when tool is not in use to prevent accidental start-up.
WARNING:
Ensure there is adequate clearance for tool and operator hands.
WARNING:
Do not operate this tool without deflector, pintail catcher bag or pintail collection bottle in place.
CAUTION:
Do not use beyond the design intent.
The tool is shipped with a red plastic plug in the air inlet connector. The connector has a 1/4-18 female pipe thread to accept user air
hose fitting. The tool comes with oil and is ready to use.
1. Remove red plastic shipping plug from Swivel (A-249) (air inlet) and screw in your quick disconnect (air) fitting.
2. Attach Deflector (200232) to rear of head cylinder assembly (704108). Rotate deflector (200232) away from operator or other
people working in the vicinity.
3. Connect tool to air hose with 90 psi. (6.2 bar) using clean, dry air. 3/8" (9.52 mm) minimum diameter air line is recommended.
Cycle tool five times by depressing and releasing actuator lever assembly (704343).
4. Disconnect air hose from tool.
5. Select proper nose assembly (see accessories pg. 18 for more information). Screw collet onto piston and slide anvil over collet and
secure with jam nut (70820). (See proper data sheet for further instructions).
6. Connect air supply.
USER QUICK
DISCONNECT FITTING
AIR HOSE
GB704 S/N: 3213 AND ABOVE
PLEASE CONTACT GAGE BILT FOR ALL OTHER SERIAL NUMBERS.

HOW TO SET-UP THE GB704

MUST
read and understand all warnings and cautions.
the air lines and/or hydraulic hoses are not a trip hazard.
HEAD CYLINDER
DEFLECTOR
RED SHIPPING
AIR INLET
Image may not reflect actual tool.
NOSE ASSEMBLY
FASTENER
ACTUATOR
8