Grease Guardian D1 Посібник з монтажу, експлуатації та технічного обслуговування - Сторінка 7
Переглянути онлайн або завантажити pdf Посібник з монтажу, експлуатації та технічного обслуговування для Промислове обладнання Grease Guardian D1. Grease Guardian D1 15 сторінок. Automatic grease removal unit
The time control displays the following information at
various stages of a cycle.
During a cycle both the heating element and the
motor are activated to heat up and skim fats oils
and greases. The main display flashes the message IN
CYCLE. The full cycle sequence is shown in Appendix
2 for each user option chosen.
CONTROLLER ADDITIONAL FEATURES
Heater Off Mode
When wastewater entering the unit is sufficiently
hot or if light oils are being intercepted the heater
element may not be required. With this in mind
there is an option to run cycles with the heating
element deactivated. This feature will also provide
savings on energy bills.
To disengage heating element:- from the Home
Screen hold in button "B" for 10 or more seconds.
The display appears as shown. In this mode the
system runs any cycle with only the motor running at
its normal pre-set operation.
See bottom of Appendix 2 for overview of timer
sequence, for "HEATR OFF MODE".
To re-engage the heater simply hold in the B button
again for 10 seconds until The "HEATR OFF MODE" is
cleared.
8
Test Mode
A test of electrical components can be conducted.
Press - and + together to access this screen from the
Home display. Next press any of the Test mode keys
to activate the
corresponding output:
Press A key to activate Heater.
Press B key to activate motor/skimmer.
Press - key to activate Output 3
Press + key to activate Output 4
Return to main menu by pressing ESC
Lid Off Alert
If the main tank cover is removed from the unit at
any time both the heater and motor will be stopped
automatically for safety reasons. The display will
flash a LID OFF alert until the lid is replaced. Power
is restored to the heater and motor after the lid is
replaced
Daily Maintenance Reminder
Once every 24 hours this reminder message
will flash on the controller display. The lid should
be removed and solids basket checked and emptied.
The grease container, internal wiper blade and grease
channel should also be checked at this time. On
replacement of lid the maintenance reminder is re-
set for another 24 hours.
Scheduled Service Reminder
The Grease Guardian unit requires periodic service
inspection and pump out by qualified personnel.
To assist, the controller is pre-set to display a service
due reminder as shown on the due date. Please
contact your Service Provider when this display
appears. The reminder will normally flash at least
once every 90 days in line with service and pump out
requirements for this product
9