Active Silicon AS-CIB-IP-001-A Посібник із швидкого старту - Сторінка 7

Переглянути онлайн або завантажити pdf Посібник із швидкого старту для Аксесуари для фотоапаратів Active Silicon AS-CIB-IP-001-A. Active Silicon AS-CIB-IP-001-A 13 сторінок. Harrier ip camera interface board
Також для Active Silicon AS-CIB-IP-001-A: Посібник із швидкого старту (7 сторінок)

Viewing Video Streams
To view streaming video from the Harrier IP Camera Interface Board you will need a media player such as
VLC media player or GStreamer. Streams can also be viewed in the ONVIF Device Manager. There are
three stream profiles available:
quality_h264
balanced_h264
bandwidth_h264
The profile to be displayed on the player is specified in the stream connection:
rtsp://<IP address>:8554/<profile>
Using VLC Media Player
Install and open
From the Media menu, select Open Network Stream
In the Open Media dialog, enter rtsp://<IP address>:8554/quality_h264
Click the Play button
Using GStreamer
Install
GStreamer
(https://gstreamer.freedesktop.org/download/)
Run the following command:
gst-launch-1.0 rtspsrc location=rtsp://<IP Address>:8554/quality_h264 latency=0
! decodebin ! autovideoconvert ! autovideosink sync=false
Note: to make GStreamer work on Windows, you may need to update the 'PATH' environment variable and
set the GStreamer environment variable; for example:
set GSTREAMER_1_0_ROOT_X86_64=c:\gstreamer\1.0\x86_64\
set path=%path%;%GSTREAMER_1_0_ROOT_X86_64%\bin;

Controlling the Camera

The ONVIF standard defines and supports control for various camera settings and client applications should
use the ONVIF Imaging service to control these camera settings (please consult the ONVIF documentation
for more information, see section 'Getting Started with the ONVIF API' below).
However, block cameras typically have many other settings/features that can be controlled using VISCA
commands sent over the camera serial interface (see figure 3). With the Harrier IP Camera Interface Board,
applications can use the ONVIF DeviceIO service to send and receive VISCA commands to the camera.
Note: applications should not use VISCA commands to change settings that are controlled by the ONVIF
Imaging service (e.g. camera resolution and frame rate).
March 2023
HARRIER IP CAMERA INTERFACE BOARD
VLC media player. (https://www.videolan.org/vlc/index.en.html)
and open a command prompt or shell.
QUICK START GUIDE
Version 1.04 – March 2023
Page 7 of 12