Aircommand Cormorant MKII Посібник з монтажу та експлуатації - Сторінка 12

Переглянути онлайн або завантажити pdf Посібник з монтажу та експлуатації для Кондиціонер Aircommand Cormorant MKII. Aircommand Cormorant MKII 16 сторінок. Aircommand cormorant mkii rooftop air conditioner

Aircommand Cormorant MKII Посібник з монтажу та експлуатації

COMMISSIONING OF THE UNIT

1. Turn the power on at the circuit breaker
2. Press the ON/OFF button and press the MODE button to
select FAN
3. Cycle through the LO, MED and HIGH fan speeds checking
that all speeds run.
4. Set mode to COOL, adjust temp via up/down buttons to at
least 3oC less than the display temp (I.e. Room temp)
compressor will start within three minutes.
5. Set mode to HEAT, similarly set temp to at least 3oC above
display temp. Compressor will start within three minutes.
After a few minutes the fan will start and warm air will be
apparent.
N.B. Regardless of the mode selected there will always be at
least a 3 minute delay before the compressor starts.

MAINTENANCE

I. Plenum Filters
The plenum filters are the only parts that require routine
maintenance. They must be cleaned periodically to ensure
that they do not become clogged with dust and other
particles.
To clean the two plenum filters, first remove them both from
the plenum by pulling them out of the assembly.
Fig 17 shows the plenum filter when removed
The state of the filters can be ascertained from its appearance,
the filters are translucent, and if they appear clogged then
they should be cleaned. Generally the filters can be cleaned
sufficiently by tapping them together to shake loose the dust
and particles trapped inside.
WARNING
Airborne particles can pose a health risk, particulalry to
young children and the elderly. Ensure that filters are cleaned
in a safe and well ventilated area
If a more thorough clean is required then the filters can be
washed out using warm soapy water. Care must be taken to
avoid ripping the fabric.
The filters should be cleaned every two weeks or more when
in use. Prolonged use, higher concentrations of airborne
particles and various other factors may result in the filters
needing to be cleaned more often.
Replacement filters can be ordered directly from Aircommand.
II. Mounting Bolts
Aircommand suggests that the hold down bolts are initially
checked for tightness within the first 3 months of installation,
and thereafter every 12 months if the van is in constant use.
III. Storage
The air conditioner should be run on a routine basis to ensure
the components remain in working order.
If the van is in storage or is to remain unoccupied for an
extended length of time it is recommended than the air
conditioner is allowed to run uninterrupted for 20-30min once
every six months.
For long term storage outdoors, or to protect your
CORMORANT from winter storms and weathering when not in
use, a protective cover can be purchased from Aircommand,
please call for details.
IV. Warranty Claims
The unit comes with a one year manufactures warranty from
date of purchase. It is IMPORTANT that you read and
understand the conditions of the warranty agreement which
are included with the unit.
If you have a claim please contact Aircommand directly on
(08) 8345 8444 alternatively you can fax (08) 8243 0628 or
email
Please have your unit serial number ready