Gaggenau CX 491 Короткий посібник
Переглянути онлайн або завантажити pdf Короткий посібник для Варильна поверхня Gaggenau CX 491. Gaggenau CX 491 2 сторінки. Full surface induction cooktop
CX 491 610
Stainless steel frame
Width 36" (90 cm)
Installation accessories
In combination of several Vario
cooktops, connecting strips must be
used.
Choose respective VA 420 strip from
one of the below, depending on type
of installation.
VA 420 010
Connection strip for
surface-mount
installation
without
appliance cover.
VA 420 011
Connection strip for
surface-mount
installation
with
appliance cover.
VA 420 000
Connection strip for
flush
installation
without
appliance cover.
VA 420 001
Connection strip for
flush
installation
with
appliance cover.
VA 450 900
36" stainless steel adjustment strip.
Necessary accessory in a combina-
tion of 15" Vario(s) with at least one
cover adjacent to a 36" cooktop. VA
450 strip will compensate the
appliance depth.
Optional accessories
GN 232 110
Teppan Yaki plate made of multi-ply
material, 13" x 21".
GN 232 230
Teppan Yaki plate made of multi-ply
material, 13" x 14.
GN 340 230
Gastronorm roaster
Non-stick cast-aluminum
4" deep, with 2 ½" lid, GN ⅔
GP 900 001
Stainless steel 6" frying pan
Non-stick cooking.
GP 900 003
Stainless steel 8" frying pan
Non-stick coating.
Full surface induction cooktop
CX 491
– One large cooking surface
– Free positioning of cookware
– Cookware of any shape and size
can be used
– TFT touch display for an intuitive
control of all functions
– Max. power output for large
cookware of up to 4,600 W with
Power boost function
– Precision-crafted ⅛-inch stainless
steel frame
– For surface-mount installation with
a visible edge or for flush
installation
– Can be perfectly combined with
other Vario 400 series products
Cooking zones
One unique cooking surface allows for
cookware as small as 3" and as large
as 13" x 21".
Up to 4 items of cookware can be
placed simultaneously on the cooktop.
Operation
Large 6.5" color graphic TFT touch
display with an easy-to-use display
concept.
Electronic power control in 17
output levels.
Features
Power boost function.
Individual pot detection.
Timer for each cooking position.
Short-term timer.
Information key with use indicators.
Power management.
Safety
Main switch.
Residual heat indicator.
Child lock.
Display cleaning protection.
Planning notes
Depending on the type of installation
(surface-mounted or flush-mounted),
the specific definition of the cut-out
must be observed.
When using the appliance cover
VA 440 or adjustment strip VA 450
additional space for cut-out depth
needs to be considered.
In a combination of Vario cooktops
with at least one appliance cover, the
adjustment strip VA 450 is required.
In a combination of several Vario 400
series cooktops a connection strip
must be used.
Depending on the type of installation—
surface- or flush-mounted, with or
without cover — the respective VA 420
connecting strip must be used.
For flush installation the edge height
in the cut-out needs to be at least ½"
and for surface-mount ⅜". Ensure a
continuous cut surface of 90°.
The weight capacity and stability,
especially in case of thin counter tops,
must be supported using suitable
substructures. Take the appliance
weight and additional loads into
account.
Flush installation is possible in
countertops made of stone, synthetics
or solid wood. Heat resistance and
watertight sealing of the edges must
be observed. For other materials,
please consult with your countertop
manufacturer.
The groove must be continuous and
even, so that uniform placing of the
appliance on the gasket is ensured.
Do not use discontinuous lining.
Operates with magnetic (induction)
iron pots and pans only. For an optimal
heat distribution, the use of sandwich
bottom cookware is recommended.
Immersion depth depending on
installation situation, 3 ³⁄₁₆" for surface-
mount or 3 ⁵⁄₁₆" for flush-mount.
Intermediate shelf is required.
Appliance can be snapped into the
countertop from above.
Please read additional planning notes
on combinations with Vario 400 series
cooktops on pages 82 – 87.
Please read the installation details
regarding air ducting on page 121.
Rating
Total rating: 7.2 kW.
Total Amps: 40 A.
208/220–240 V / 60 Hz
Plan for a 37" connecting cable
without plug (hardwire required).