Gaggenau GI 976 760 Посібник - Сторінка 7

Переглянути онлайн або завантажити pdf Посібник для Посудомийна машина Gaggenau GI 976 760. Gaggenau GI 976 760 14 сторінок.

ELECTRICAL PREPARATION

WARNING
THESE INSTALLATION
INSTRUCTIONS ARE
INTENDED FOR USE BY
QUALIFIED INSTALLERS
Electrical Supply
It is the customer's responsibility to insure
that the dishwasher installation is in
compliance with all national and local
electrical codes and ordinances.
dishwasher is designed to operate with a
120V, 60Hz, AC only electrical supply.
Connect to a separate electrical circuit with
a fuse or circuit breaker rated for 15 Amps.
A 20 Amp fuse or circuit breaker may be
used if the dishwasher is connected with a
food disposer, but not more than 20 Amps.
Electrical supply conductors shall be copper
and shall be minimum 16." The dishwasher
should be properly grounded, positioned
as shown in Figure 9, and should be installed
by a qualified electrician. No other
appliances or outlets should be connected
to this circuit.
• Cut a 1" (25.4mm) diameter hole in the
cabinet (in area of Figure 9 B). For wood
cabinets, sand the hole until smooth.
For metal cabinets, cover the edge with
a grommet.
• Run flexible cable (as codes permit) from
junction through hole in cabinet. Cable
should extend 30" (762 mm) from back
wall.
Figure 8
The
Electrical Rating
Table 3
Openings for electrical lines must be
installed in the marked areas as
shown in Figures 8 and 9 to avoid
interference with the dishwasher
frame or other components.
Shut-off
valve
HWS
Hot water supply line
Figure 9
www.gaggenau.com/us
23-5/8"-24-1/8"
(600-613mm)
3-1/2
(90 mm)
1-5/16
(49 mm)
A
B
14"
(355 mm)
21"
(533 mm)
Electric supply cable
ENGLISH - 7